3.
INSTALLATION
3.1
Preliminary Checks
Before the installation, to ensure correct working of the automation, please check the followings:
•
Make sure the gate's structure is suitable to be automated
•
Check the weight, dimensions and type of the gate is appropriate to this type of automation.
•
Ensure the gate is able to open and close smoothly and is free of obstacles that may cause the gate to derail.
•
Check the ground and all surfaces for the installation are suitable for stable and safe fixing of the gate automation.
•
Make sure the installation area for the automation is wide enough to accommodate the anchor plate and that
the motor can be accessed easily in the event of power cuts.
•
Ensure the location where the automation is installed is not exposed to flood hazards; if in doubt raise the automation
above ground level.
•
In cases where the automation has to be installed in a vehicles path or parking area, it is recommended to protect
it against accidental damage.
•
Ensure an efficient earth connection system is in place.
•
Make sure the surfaces for photocells fixing areas are flat and smooth enough to allow a perfect alignment
between transmitting and receiving units. They must both directly see each other as they are not reflective.
3.2
Electrical Set-up
3.2.1 STANDARD INSTALLATION
3.2.2 ELECTRICAL CABLES SPECIFICATIONS
The cables required the electrical set-up (not included in the pack) may vary according to quantity and
type of devices installed.
A
Safety edge
B
Power supply
C Photocells
C¹ Photocells
D
Key-switch
E
Flashing light
3
D
A
230V
2x0,50
mm²
2x1,50+T
rx 4x0,50 mm²
tx 2x0,50 mm²
2x0,50
mm²
2x0,50
mm²
E
C
C
B
01_2015