Installation; Preliminary Checks; Standard Installation; Electrical Cables Specifications - Proteco MOVER 5 Installation Manual

Opener for rack-driven sliding motor
Hide thumbs Also See for MOVER 5:
Table of Contents

Advertisement

3.

INSTALLATION

3.1

Preliminary Checks

Before the installation, to ensure correct working of the automation, please check the followings:
Make sure the gate's structure is suitable to be automated
Check the weight, dimensions and type of the gate is appropriate to this type of automation.
Ensure the gate is able to open and close smoothly and is free of obstacles that may cause the gate to derail.
Check the ground and all surfaces for the installation are suitable for stable and safe fixing of the gate automation.
Make sure the installation area for the automation is wide enough to accommodate the anchor plate and that
the motor can be accessed easily in the event of power cuts.
Ensure the location where the automation is installed is not exposed to flood hazards; if in doubt raise the automation
above ground level.
In cases where the automation has to be installed in a vehicles path or parking area, it is recommended to protect
it against accidental damage.
Ensure an efficient earth connection system is in place.
Make sure the surfaces for photocells fixing areas are flat and smooth enough to allow a perfect alignment
between transmitting and receiving units. They must both directly see each other as they are not reflective.
3.2
Electrical Set-up

3.2.1 STANDARD INSTALLATION

3.2.2 ELECTRICAL CABLES SPECIFICATIONS

The cables required the electrical set-up (not included in the pack) may vary according to quantity and
type of devices installed.
A
Safety edge
B
Power supply
C Photocells
C¹ Photocells
D
Key-switch
E
Flashing light
3
D
A
230V
2x0,50
mm²
2x1,50+T
rx 4x0,50 mm²
tx 2x0,50 mm²
2x0,50
mm²
2x0,50
mm²
E
C
C
B
01_2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mover 8Cat 8Mover 15Mover 15tCat 5