T90xr pumped electric shower

INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY

Instructions for installers and service engineers only
CLeANING THe FILTeR
Fig.
It is recommended that the filter is periodically
cleaned in order to maintain the performance of
the shower. It is essential that this operation is
carried out by a competent person.
SwItch off thE ElEctRIcIty SUPPly at
thE maInS.
Remove the cover and disconnect the plug.
Note: Should debris be trapped on the shut
off seat inside the valve, water will continue to
flow out as the filter is removed. It is advisable
to switch off the incoming water supply before
removing the filter.
DO nOT rely on the filter shut off valve when
carrying out repairs or service to other areas of
the shower unit.
unscrew the filter (fig.) by turning anti-
clockwise. Remove the unit complete with the
filter and wash under running water. Make sure
all debris is removed.
Replace by pushing the unit back into its
housing until the threads engage and then
turn fully clockwise until tight. DO nOT
OVERTIGHTEn.
Before replacing the cover, it is strongly advised
to prime the unit by opening the bleed screw
until water drains from it.
Close the bleed screw and connect the plug to
the cover. Replace the cover and secure with the
fixing screws.
Switch on the electric supply and start the
shower on the COLD SETTInG OnLy and with
the temperature control rotated fully anti-
clockwise.
When a smooth flow of water is obtained, the
shower can then be used in the normal manner.