Redundant Power Supply Blank - HP proliant ML110 gen9 Maintenance And Service Manual

Hide thumbs Also See for proliant ML110 gen9:
Table of Contents

Advertisement

Remove all power:
4.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on a sturdy, level surface.
5.
Remove the access panel (on page 24).
6.
If installed, remove the PCI air baffle (on page 25).
7.
Remove the system air baffle (on page 26).
8.
Disconnect all power supply cables from the system board, drive cages, and devices.
9.
Remove the hot-plug power input module from the power supply bay.
10.
To replace the component, reverse the removal procedure.

Redundant power supply blank

CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
Power down the server (on page 24).
1.
Access the product rear panel.
2.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
Removal and replacement procedures 66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents