6. Thermo switch 3
• Remove the thermo switch 3 from the radi-
ator.
• Connect the pocket tester (Ω × 1) to the
thermo switch 3 1.
• Immerse the thermo switch 3 in coolant 2.
• Check the thermo switch 3 for continuity.
While heating the coolant use a thermom-
eter 3 to record the temperatures.
È The thermo switch 3 circuit is closed.
É The thermo switch 3 circuit is open.
Test step Coolant temperature Continuity
Less than 75 ± 3 °C
1
(167 ± 5.4 °F)
More than 75 ± 3 °C
2
(167 ± 5.4 °F)
More than 68 °C
3
(154.4 °F)
Less than 68 °C
4
(154.4 °F)
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
WARNING
Handle the thermo switch 3 with special
care.
Never subject it to a strong shock or allow
it to be dropped. Should it be dropped, it
must be replaced.
Thermo switch 3
28 Nm (2.8 m · kg, 20 ft · lb)
*
No
Yes
Yes
No
GOOD
CONDITION
9 - 50
COOLING SYSTEM
BAD CONDITION
Replace the thermo switch 3.
+