Fan Speed Control For Indoor Unit - Daikin FTXS20K2V1B Service Manual

Inverter pair wall mounted type ftxs/atxs-k series
Hide thumbs Also See for FTXS20K2V1B:
Table of Contents

Advertisement

SiBE041134EB
1.4

Fan Speed Control for Indoor Unit

Outline
Phase control and fan speed control contains 9 steps: LLL, LL, SL, L, ML, M, MH, H, and HH.
The airflow rate can be automatically controlled depending on the difference between the room
thermistor temperature and the target temperature.
Automatic Fan
In automatic fan speed control, the step SL is not available.
Speed Control
LLL
LL
L
ML
M
MH
H
HH (POWERFUL)
Cooling
The following drawing explains the principle of fan speed control for cooling.
*The upper limit is M tap in 30 minutes from the operation start.
Heating
In heating operation, the fan speed is regulated according to the indoor heat exchanger
temperature and the difference between the room thermistor temperature and the target
temperature.
COMFORT
AIRFLOW
Operation
Functions and Control
Step
= The airflow rate is automatically controlled within this range when the FAN setting
button is set to automatic.
Fan speed
+2.5°C
+1.5°C
+0.5°C
The fan speed is controlled automatically.
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
Cooling
Heating
(R11681)
(R6834)
Room thermistor temperature – target temperature
MH*
+3°C
M
+2°C
ML
+1°C
L
Main Functions
(R14588)