IT IS IMPORTANT THAT A VOLTAGE READING
BE MADE AT THE COMPRESSOR MOTOR
ELECTRICAL CONNECTIONS, WHILE THE UNIT
IS IN OPERATION TO VERIFY THE CORRECT
VOLTAGE REQUIRED BY THE COMPRESSOR
IS BEING SUPPLIED. LOW OR HIGH VOLTAGE
CAN DETRIMENTALLY AFFECT OPERATION
AND THEREBY VOID ITS WARRANTY.
IT IS IMPORTANT THAT YOUR UNIT HAS
ITS OWN DEDICATED LINE. CONDENSING
UNITS ARE DESIGNED TO OPERATE WITH
A VOLTAGE FLUCTUATION OF PLUS OR
MINUS 10% OF THE VOLTAGE INDICATED
ON THE UNIT DATA TAG. BURN OUT OF A
CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
ELECTRICAL SUPPLY
Any wiring should be done by a qualified electrician in accordance with local electrical
codes. A properly wired and grounded outlet will assure proper operation. Please
consult the data tag attached to the compressor to ascertain the correct electrical
requirements. Supply voltage and amperage requirements are located on the serial
number tag located inside the mechanical housing.
BULLET-FEET ADJUSTMENT
The legs are equipped with bullet-type leveling bolts. Turn bolts clockwise or
counterclockwise until the unit is level (both right to left and front to back). This can be
done by hand or with an open end wrench.
Installation
OM-51000 & 53000 SERIES
9