Introduction

Solitude (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air extraction in
small/medium-sized rooms. Suitable for air discharge directly to the outside or in the presence
of short ducted system.
Wall, ceiling or window installation (fig.2).
Read this manual carefully before using the product and keep it in a safe place for reference.
This product was constructed up to standard and in compliance with regulations relating to electrical
equipment and must be installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this
booklet.

TECHNICAL SPECIFICATIONS

• Material: High quality, impact and UV-resistant ABS colour RAL 9010.
• Design front cover removable for cleaning without the use of tools.
• Rear reinforcement ring to prevent spigot deformation during installation.
• High efficiency aerodynamic fan with "winglet" blades to optimise quietness and efficiency.
• Single phase EC Brushless motor with integral thermal protection.
• Motor mounted on high quality ball bearings.
• The fan is double insulated: no earth connection is required.
• Trickle speed selectable during installation (see fig.16)
• Option to boost from trickle through LS connection.
• Installation type selection available (through wall or ducted).
• Integral over-run timer.
• IPX4 degree of protection.
• Power supply 220V to 240V~ 50Hz.
Model
Airflow
m
/h
3
Solitude
83/47/36/29/21

PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE

• The device should not be used for applications other than those specified in this manual.
• After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging
within the reach of small children or people with disabilities.
• Do not touch the appliance with wet or damp hands/feet.
• The device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities or those with a lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the device from a person responsible for their safety.
Children should be supervised to ensure that they do not play with the device.
• Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
• If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use
original spare parts only for repairs.
• The electrical system to which the device is connected must comply with regulations.
• Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
• The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from
any type of combustion unit. It must expel air outside via its own special duct.
• Operating temperature: 0°C up to +50°C.
• The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
1
Static pressure
Power
Pa max
W max
l/s
27
23/13/10/8/6
Sound pressure
dB(A) @3m
2.5
26/23/13/19/11
Fig. 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the solitude and is the answer not in the manual?

Questions and answers

Summary of Contents for Titon solitude

  • Page 1 Solitude - dMEV unit Fig. 1 Introduction Solitude (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air extraction in small/medium-sized rooms. Suitable for air discharge directly to the outside or in the presence of short ducted system.
  • Page 2 • Solitude dMEV fans include an airflow sensor which monitors the flow rate and adjusts the speed to maintain this flow. Excessive dust or other contaminants may impair the sensor accuracy. Periodic cleaning (e.g. vacuum cleaner) is recommended to remove dust from the fan housing and flow sensor.
  • Page 3 INSTALLATION (Fig.2) perimetrical exhausting wall ceiling (accessory on demand) window (kit on demand) direct exhausting short ducting...
  • Page 4 MOUNTING AND ELECTRICAL WIRING Solitude= ø99 mm...
  • Page 5 SURFACE CABLE 4 x ø 5 mm H03VV-F ; H05VV-F 3 X 0.5 ÷ 1.5 mm 4 X 0.5 ÷ 1 mm ø 10mm...
  • Page 6 RECESSED CABLE ENTRY 4 x ø 5 mm H03VV-F ; H05VV-F 3 X 0.5 ÷ 1.5 mm 4 X 0.5 ÷ 1 mm...
  • Page 7 TIMER Solitude JUMPER INSTALLATION AIRFLOW constant flow /h - 13l/s constant flow /h - 10l/s  constant flow /h - 8l/s  constant flow /h - 6l/s   in room /h - 13l/s  in room /h - 8l/s ...