Installing and connecting the device
3.2 Installing the device
Instructions for wall mounting
Mounting examples
Material
Concrete
Plasterboard
(at least 13 mm
thick)
Metal
(at least 2 mm thick)
Personal injuries or material damage in the case of insufficient load-bearing capacity of wall
The device could fall if the wall to which it is mounted has insufficient load-bearing capacity.
This can result in personal injuries or material damage.
Ensure that the wall is capable of bearing four times the total weight of the device (including
the brackets and expansion modules). The total weight of the device is approximately 7 kg.
30
Hole diameter
8 mm diameter,
60 mm depth
14 mm diameter
5 mm diameter
WARNING
Mounting
Dowel: 8 mm diameter, 50 mm length
screws 4.5-6 x 50 mm
Tilting dowel: 4 mm diameter,
at least 50 mm long
Metal screws: 4 mm diameter,
at least 15 mm long