Bios Update - Siemens SIMATIC IPC627D Operating Instructions Manual

Industrial pc
Hide thumbs Also See for SIMATIC IPC627D:
Table of Contents

Advertisement

Technical specifications
8.6 BIOS description
Boot > Legacy
System parameters
Normal Boot menu
Boot Type Order
Floppy drive
Hard Disk Drive
CD/DVD ROM Drive
USB
Others
Exit
System parameters
Profile:
8.6.6

BIOS update

Check regularly if updates are available for download to your device.
Additional information can be found on the Internet at the following address:After Sales
Information system (http://www.siemens.com/asis).
Noting down and restoring BIOS Setup settings
NOTICE
Irretrievable loss of data
All BIOS Setup settings are deleted after the BIOS update. This can put the system in an
undefined state. This may damage the device and the plant.
1. Print out the table in the next section "General BIOS Setup settings".
2. Enter your specific BIOS Setup setting in this table before you run a BIOS update.
3. Start BIOS Setup after the BIOS update.
4. Load the BIOS Setup default settings with <F9> "Setup Defaults". Or use the BIOS
5. Make your own Setup settings based on the table you have printed out.
6. Save the BIOS Setup settings with <F10> "Save and Exit".
156
Setup command "Load Optimal Defaults" in the "Exit" menu.
Default settings
Standard
In the order of the following boot media:
Depending on configuration
Depending on configuration
Depending on configuration
Depending on configuration
Depending on configuration
Default settings
Operating Instructions, 09/2014, A5E32990859-AB
Local settings