Preamp Gain; Specifications - Shure MX405 User Manual

Microflex gooseneck microphones and accessories
Hide thumbs Also See for MX405:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Button Configuration
For logic control operation, DIP Switch 1 determines the button be-
havior (DIP Switch 2 has no effect).
Button Behavior
Momentary: When pushed, SWITCH OUT (red
wire) falls to 0 V. When released, SWITCH OUT
returns to +5 V.
Toggle: Push and release sets SWITCH OUT to 0
V. Push again to toggle back to +5 V.
Controlling the LED Using Logic LED IN
When configured for logic mute control, connect the LED IN con-
ductors to an external switch, relay, or a TTL gate (gate out) on an
automatic mixer. The MX400DB contains an internal pull-up resis-
tor circuit.
• The LED illuminates green/red when the MX396 LED IN is
grounded (orange wire connected to the green wire).
• The LED illuminates red/off when LED IN is lifted (orange wire
is NOT connected to the green wire).

Preamp Gain

If necessary, the preamplifier gain can be reduced by 12 dB.
Contact an authorized Shure service center for information.

Specifications

Cartridge Type
Electret Condenser
Frequency Response
50–17000 Hz
Polar Pattern
MX405/C, MX410/C, MX415/C
Cardioid
MX405/S, MX410/S, MX415/S
Supercardioid
Output Impedance
170 Ω
Output Configuration
Active Balanced
Sensitivity
@ 1 kHz, open circuit voltage
6
Cardioid
−35 dBV/Pa (18 mV)
Supercardioid
−34 dBV/Pa (21 mV)
1 Pa=94 dB SPL
DIP Switch
Maximum SPL
Setting
1 kHz at 1% THD, 1 kΩ load
Cardioid
121 dB
Supercardioid
120 dB
Equivalent Output Noise
A-weighted
Cardioid
28 dB SPL
Supercardioid
27 dB SPL
Signal-to-Noise Ratio
Ref. 94 dB SPL at 1 kHz
Cardioid
66 dB
Supercardioid
68 dB
Dynamic Range
1 kΩ load, @ 1 kHz
93 dB
Common Mode Rejection
10 to 100,000 kHz
45 dB, minimum
Preamplifier Output Clipping Level
at 1% THD
−8 dBV (0.4 V)
Polarity
3-pin XLR
Positive sound pressure on diaphragm produces
positive voltage on pin 2 relative to pin 3 of output
XLR connector
5-pin XLR
Positive sound pressure on diaphragm produces
positive voltage on pin 4 relative to pin 2 of output
XLR connector
Net Weight
MX405
0.054 kg (0.119 lbs)
MX410
0.068 kg (0.150 lbs)
MX415
0.07 kg (0.154 lbs)
MX400DP
0.516 kg (1.138 lbs)
MX400SMP
0.125 kg (0.275 lbs)
Logic Connections
LED IN
Active low (≤1.0V), TTL compatible. Absolute
maximum voltage: -0.7V to 50V.
LOGIC OUT
Active low (≤1.0V), sinks up to 20mA, TTL
compatible. Absolute maximum voltage: -0.7V
to 50V (up to 50V through 3kΩ).
Mute Switch Attenuation
-50 dB minimum
Cable
MX400DP
6.1 m (20 ft) attached cable with shielded audio pair terminated
at a 3-pin male XLR and three unterminated conductors for logic
control
Environmental Conditions
Operating Temperature
–18–57°C (0–135°F)
Storage Temperature
–29–74°C (–20–165°F)
Relative Humidity
0–95%
Power Requirements
Phantom Power
48–52 V DC, 8.0 mA
Certifications
This product meets the Essential Requirements of all relevant
European directives and is eligible for CE marking.
The CE Declaration of Conformity can be obtained from: www.
shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Email: info@shure.de

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx400smpMx400dpMx410Mx415

Table of Contents