Flushing - Graco ULTRA 600 231–307 Series A Instructions-Parts List Manual

Airless paint sprayer electric 120 vac
Table of Contents

Advertisement

When to flush
Determine the material you are going to pump from the
Column 1, then flush with the material indicated in the
Column 2, then, depending on what you plan to do
next, follow the recommendations in one of the next
three columns.
Column 1
If you are going to:
Spray latex paint
Spray oil paint
Change latex to oil paint
Change oil to latex paint
Change colors, same base Compatible solvent
How to flush
1. Follow Pressure Relief Procedure. See page 11.
2. Remove the spray tip and clean it separately. If
you are changing from water–based to oil–based
paints or solvents, be sure that the tip is cleaned
thoroughly.
3. Remove the filter screen and then reinstall the
bowl, hand tight, without the screen. Clean the
screen separately. See Fig. 10.
BOWL
Fig. 10

Flushing

Column 2
Flush with:
Prime with:
Warm, soapy water,
Latex-base paint
then clean water
Mineral spirits
Oil–base paint
Warm, soapy water,
Mineral spirits
then clean water
Mineral spirits,
Latex
soapy water, and
clean water.
such as water or
mineral spirits
SCREEN
02990
CAUTION
NEVER leave water or water-based fluids in the
sprayer if there is a chance it could freeze. Push
the water out with mineral spirits. Frozen fluid in
the sprayer prevents it from being started and may
cause serious damage.
Column 3
Column 4
Clean with:
Warm soapy water,
then clean water
Mineral spirits
Mineral spirits
Warm, soapy water,
then clean water
4. Pour one-half gallon (2 liters) of compatible solvent
into a grounded metal flushing pail. Put the suction
hose in the pail.
5. Open the pressure drain valve. See Fig.11.
6. To save the paint still in the pump and hose,
follow Step 7, except put the drain hose in the
paint pail. When solvent appears, close the drain
valve. Put the drain hose in the flushing pail. Trig-
ger the gun into the paint pail. When solvent ap-
pears, release the trigger. Continue with Step 7.
Column 5
Store unit with:
Mineral spirits
Mineral spirits
Mineral spirits
Mineral spirits

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultra 600 231–325 series a

Table of Contents