Shutdown And Care - Graco ULTRA 600 231–307 Series A Instructions-Parts List Manual

Airless paint sprayer electric 120 vac
Table of Contents

Advertisement

WARNING
To reduce the risk of serious bodily injury, always
follow the Pressure Relief Procedure Warning on
page 3 when instructed in this procedure to
relieve pressure.
1. Check the packing nut/wet-cup daily. Relieve
pressure first. Keep the wet-cup 1/3 full of TSL at
all times to help prevent fluid buildup on the piston
rod and premature wear of packings.
2. Tighten the packing nut/wet-cup just enough
to stop leakage. Over-tightening causes binding
and excessive packing wear. Use a round punch
or brass rod and a light hammer to adjust the nut.
See Fig. 8.
3. Clean the gun's fluid filter often and whenever
the gun is stored. Relieve pressure first. Refer to
manual 307–614.
4. Lubricate the bearing housing after every 100
hours of operation. Remove the front cover. Apply
several drops of SAE 10 non-detergent oil in the
bearing housing cavity (B). See Fig. 9.
5. Flush the sprayer at the end of each work day
and fill it with mineral spirits to help prevent pump
corrosion and freezing. See page 15.
CAUTION
To prevent pump corrosion, and to reduce the
chance of fluid freezing in the pump in cold
weather, never leave water or any type of paint in
the sprayer when it is not in use. Freezing can seri-
ously damage the sprayer or result in a loss of
pressure or stalling.
6. For very short shutoff periods, leave the suction
hose in the paint, relieve pressure, and clean the
spray tip.

Shutdown and Care

7. Coil the hose when storing it, even for overnight,
to help protect the hose from kinking, abrasion,
coupling damage, etc.
WARNING
See the warning section HOSE SAFETY on page
4 for information on the hazard of using damaged
hoses.
Turn packing
nut clockwise to
tighten
Fig. 8
Fig. 9
02988
B
02989