WARNING:
• Due to the high pressures within the refrigeration circuit, under no
circumstances must direct heat be applied to the evaporator coil in an
attempt to remove the build up of ice.
• No attempt should be made to cut open any part of the refrigeration circuit
due to high pressures and gas involved. If the unit is switched off at the
mains power supply for any reason, the unit must be allowed to stand at
rest for at least three minutes before restarting. Failure to do so may cause
the unit to blow the fuses owing to the compressor due to there being a
refrigerant imbalance.
SETTING THE ADJUSTABLE HUMIDISTAT:
The positioning of the humidistat depends on the application the CD100 is
being used for and the conditions within the area to be dried. The following
table can be used as a guide:
WAREHOUSES

INDICATOR PANEL

The CD100 is fitted with an indicator lamp to show when power is available
and when the unit is switched on.
If the unit does not appear to be functioning correctly refer to the repairs
section.
APPLICATION
FACTORIES
BASEMENTS
DEFLOODING
Page 6 of 16
Drawing : - TPC262
Issue
Date
HUMIDISTAT
SETTING
60%
50%
50%
40%
: - 5
: - 05/01/12