GE GEMX50-W1 Installation Manual

GE GEMX50-W1 Installation Manual

Tetra wet location max led lighting system

Advertisement

Quick Links

GE
Lighting
Tetra
Wet Location MAX
®
LED Lighting System
GEMX71-W1, GEMX50-W1, GEMX41-W1, GEMX32-W1, GEMXH71-W1, GEMXH50-W1,
GEMXH41-W1, GEMXH32-W1, GEMXRD-W1, GEMXBL-W1, GEMXGL-W1, GEMXPO-W1,
GEMXRC-W1, GEMXYG-W1, GEMXHRD-W1

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground Tetra
power supply enclosure.
®
RISK OF FIRE
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG (0.82mm
• Follow all NEC and local codes.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment
is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to
correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard
ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003
du Canada.
imagination at work
WARNING/AVERTISSMENT
)
2
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation avant l'inspection, l'installation ou le déplacement.
• Assurez-vous de correctement mettre à terre l'alimentation électrique Tetra
RISQUES D'INCENDIE
• N'utilisez que des fils approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82mm
• Respectez tous les codes NEC et codes locaux.
Prepare Electrical Wiring
Electrical Requirements
• Acceptable for use in dry, damp and wet locations.
• The grounding and bonding of the LED Driver shall
be done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
Tips
• For optimal light uniformity in halo-lit applications the Tetra
modules should be mounted on UL recognized plastic and the light
output from the Tetra
sign enclosure. This will allow for uniform backlighting of the sign
and will provide simple mounting for the Tetra
• A best practice for the supply wire at the point at which it is brought
into the sign is to have a drip loop on the inside of the letter to keep
water from collecting on the Tetra
• These products are not required to be enclosed or protected from
weather.
This product is intended solely for the use of non-residential signage
lighting and is not intended for use in any other applications.
Conforms to the following standards: IP66 rated
Installation Guide
)
2
LED system should be directed back into the
®
LED system.
®
LED strip.
®
12
Volt
.
®
LED
®

Advertisement

loading

Summary of Contents for GE GEMX50-W1

  • Page 1: Before You Begin

    Installation Guide Lighting Volt Tetra Wet Location MAX ® LED Lighting System GEMX71-W1, GEMX50-W1, GEMX41-W1, GEMX32-W1, GEMXH71-W1, GEMXH50-W1, GEMXH41-W1, GEMXH32-W1, GEMXRD-W1, GEMXBL-W1, GEMXGL-W1, GEMXPO-W1, GEMXRC-W1, GEMXYG-W1, GEMXHRD-W1 BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES...
  • Page 2 Components UL approved 18 AWG supply wire (0.82 mm UL approved 22-14 AWG twist-on wire connectors (0.33 - 2.08 mm ) or 18-14 AWG In-line/IDC connectors (0.82 - 2.08 mm #6 or #8 (M3 or M4) screws, 1/8 inch (3.2 mm) rivets, or electronic grade silicone or equivalent Tetra ®...
  • Page 3 Electrical Connections White (-) Red (+) Cap wires Connect LED strips using in-line (IDC) connectors or Must cap all exposed wires with appropriate wire twist-on wire connectors. connectors. To Tetra LED System Red (+) To power supply Black or blue (-) Red (+) Black or blue (-) Red (+)
  • Page 4: Troubleshooting

    GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. © 2016 GE.

This manual is also suitable for:

Gemx32-w1Gemx71-w1Gemxh71-w1Gemx41-w1Gemxh41-w1Gemxh50-w1 ... Show all