Electrical Connections
White (-)
1
Connect LED strips using in-line (IDC) connectors or
twist-on wire connectors.
Red (+)
3
Run a wire from the Power Supply to each channel
letter and connect to the first LED module on the
strip.
Must be used with Tetra ® 12 Volt Power Supplies.
Retrofit Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure
that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have
a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated
transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or
country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in
all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum
or zinc coated steel patch with rivets and sealant.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen. Follow
the manufacturer's directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount
the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A Tetra
12VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the
®
number of Tetra
Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload
®
the Tetra
Class 2 Power Supply chosen.
®
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the
power supply installation guide.
11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country electrical codes.
Red (+)
To Tetra LED System
Black or blue (-)
Power
Supply
2
Must cap all exposed wires with appropriate wire
connectors.
White (-)
4
Connect the red wire (+) of the LED strip to the red
wire (+) of the power supply. Connect the white
wire (-) of the LED strip to the black or blue wire (-)
of the power supply.
NOTE: All electrical connections should be made
within the letter.
Cap wires
Red (+)
To power
supply
Black or blue (-)
Red (+)