CBX800 INSTALLATION MANUAL
BAUDRATE SELECTION
The Host network baudrates cannot be set through the rotary switches.
When the Network Type is used for ID-NET™ network Slaves, the ID-NET™ baudrate is selected through the
x100 switch and must match the Master ID-NET™ baudrate. The settings are:

ELECTRICAL CONNECTIONS

POWER SUPPLY
CBX00 can accept power from the connected reading device through the 25-pin connector, or through the
dedicated spring clamp connector (see section Power Source Jumper Settings).
The default jumper setting, requires power to be supplied to the CBX800 through the Vdc and GND pins provided
on the spring clamp terminal connector as shown in Figure 13:
The power must be between 10 and 30 Vdc only.
14
ID-NET™ Baudrate Switch (x100)
0 = 19200 Baud
1 = 38400 Baud
2 = 57600 Baud
3 = 125 kBaud
4 = 250 kBaud
Power Supply
VGND
V+
Earth
in
Ground
Figure 13 - Power Supply Connections
5 = 500 kBaud
6 = 1 MBaud
7 = Reserved
8 = Reserved
9 = Reserved