ELECTRICAL FEATURES
Supply Voltage
Consumption
Limited Current Consumption
CBX + reading device consumption
(see related manual)
COMMUNICATION INTERFACES
Host Interface
Auxiliary
Data Source
ID-NET™
Communication Protocols
USER INTERFACE
LED Indicators
Configuration Modes
PHYSICAL FEATURES
Mechanical Dimensions
Weight
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Humidity max.
Vibration Resistance
EN 60068-2-6
Bump Resistance
EN 60068-2-29
Protection Class
EN 60529
The features given are typical at a 25 C ambient temperature (if not otherwise indicated).
*
for further details about minimum/maximum supply voltage refer to the manual of the connected reading
device, since the minimum supply voltage required may be >10.
** when compression connectors and reading device are correctly connected.
If Host Interface (Fieldbus) Modules are used, only correctly installed IP65 models guarantee IP protection.
Protection is not guaranteed when Standard Fieldbus Modules are mounted.
CBX800 INSTALLATION MANUAL
10 to 30 Vdc*
0.8 - 0.5 A
2.5 A
RS232/RS485 up to 115.2 Kbit/s
RS232 up to 115.2 Kbit/s
RS232/RS485 up to 115.2 Kbit/s
RS485 Half Duplex up to 1 Mbaud
Datalogic Application Driver (DAD Driver)
Power On/Polarity Error (blue/red)
Trigger (yellow)
IN2 (green)
OUT1 (yellow)
OUT2 (green)
Ready (green)
Host (yellow)
Source (green)
ID-NET (yellow)
OUT3 (green)
Genius™ utility program
Genius™ based Host Mode Programming
193 x 180 x 71 mm
(7.6 x 7.1 x 2.8 in.)
830 g. (29.28 oz.)
0° to 50 C (+32° to 122 °F)
-20° to 70 C (-4° to 158 °F)
90% non condensing
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz; 2 hours on each axis
30 g; 6 ms;
5000 shocks on each axis
IP65 **