Buderus Logamax plus GB142-24 Installation Instructions Manual page 11

Condensing
Hide thumbs Also See for Logamax plus GB142-24:
Table of Contents

Advertisement

[3]
Di electric union
[4]
DHW return 1" FPT
[5]
Low loss header
[6]
Tridicator
[7]
System return 1½ MPT
[8]
System supply 1½ MPT
[9]
Drain valve
[10] DHW supply 1" FPT
[11] Relief valve
▶ Connect the expansion tank to the system.
▶ Connect the pipes so that they are free from strain.
Connecting boiler with DHW tank
▶ Connect the external hot-water tank according to the Installation
instructions of the hot-water tank and fittings concerned.
Piping examples
▶ The following illustrations are two Installation examples.
NOTICE:
▶ The following illustrations are simplified conceptual
illustrations only.
Piping and field components must be field verified.
Fig. 10 is a schematic representation of fig. 9.
1
GB142
GB142
11
10
9
8
Fig. 10 Schematic representation of the boiler with the hydronic set
[1]
Flue gas
[2]
Air intake
[3]
Pump manifold
[4]
DHW return 1" FPT
[5]
Low loss header
[6]
PT gauge (pressure and temperature gauge)
[7]
System return 1½ MPT
[8]
System supply 1½ MPT
[9]
Drain valve
[10] Pump manifold shut-off valve
[11] DHW supply 1" FPT
Logamax plus GB142-24/30/45/60 – 6720820104 (2017/05)
2
3
4
5
6
PT
7
72150200-10.1TD
DANGER:
If this boiler is installed in a closed water supply system
with an external indirect DHW tank, such as one having a
backflow preventer in the cold water supply line, means
shall be provided to control thermal expansion.
▶ Contact the water supplier or local plumbing
inspector on how to control this situation.
Relief valve
The indirect DHW tank must have a temperature and pressure relief
valve installed. The relief valve shall comply with the Standard for Relief
Valves and Automatic Gas Shutoff Devices for Hot Water Supply
Systems, ANSI Z21.22-CSA 4.4.
▶ Install the relief valve according fig. 10. The relief valve must comply
with following specifications:
– dimensions: height 2¼ inch (57.15 mm), width 2 inch
(50.8 mm);
– 30 Psi (2 bar) discharge pressure;
– discharge is ¾ inch (19.1 mm) female in diameter.
WARNING:
No valve is to be placed between the relief valve and the
tank. Discharge of the relief valve must be conducted to
a suitable place for disposal when relief occurs and no
reducing coupling or other restriction may be installed in
the discharge line.
NOTICE:
▶ For the maximum permissible flow rate of the DHW
pump see section 1.4, page 4.
1
GB142
GB142
16
15
14
13
12
11
10
Fig. 11 Schematic representation of the boiler with the hydraulic set
connected to an optional hot water tank with one or multiple
zones including one pump and zone valves
[1]
Flue gas
[2]
Air intake
[3]
Optional DHW tank
[4]
Primary pump
[5]
Shut-off valve
[6]
PT gauge (pressure and temperature gauge)
[7]
Zone valve
6
Installation
2
3
Additional
DHW
Tank
4
5
PT
6
7
8
9
72150200-11.1TD