FLIR Ex series User Manual page 65

Hide thumbs Also See for Ex series:
Table of Contents

Advertisement

9
Technical data
Measurement analysis
Spotmeter
Area
Isotherm
Emissivity correction
Emissivity table
Reflected apparent temperature correction
Set-up
Color palettes
Set-up commands
Storage of images
File formats
Digital camera
Digital camera, resolution
Digital camera, FOV
Data communication interfaces
Interfaces
Wi-Fi
Radio
Wi-Fi
Power system
Battery type
Battery voltage
Battery operating time
Charging system
Charging time
Charging temperature
Power management
AC operation
Environmental data
Operating temperature range
Storage temperature range
#T559828; r. AK/40423/40448; en-US
Center spot
Box with max./min.
Above/below/interval
Variable from 0.1 to 1.0
Emissivity table of predefined materials
Automatic, based on input of reflected temperature
Black and white, iron and rainbow
Local adaptation of units, language, date and time
formats
Standard JPEG, 14-bit measurement data
included
640 × 480
55° × 43°
USB Micro: Data transfer to and from PC and Mac
device
Peer-to-peer (ad hoc) or infrastructure (network)
Standard: 802.11 b/g/n
Frequency range:
2400–2480 MHz
5150–5260 MHz
Max. output power: 15 dBm
Rechargeable Li ion battery
3.6 V
Approx. 4 hours at +25°C (+77°F) ambient temper-
ature and typical use
Battery is charged inside the camera or in specific
charger.
2.5 hours to 90% capacity in camera. 2 hours in
charger.
10°C to +45°C (+50°F to +113°F)
Automatic shut-down
AC adapter, 90–260 VAC input, 5 VDC output to
camera
–15°C to +50°C (+5°F to +122°F)
–40°C to +70°C (–40°F to +158°F)
57

Advertisement

Table of Contents
loading

Table of Contents