Extended mode parameter
REMARKS
indicates simple mode parameters.
The shaded parameters in the table allow its setting to be changed during operation even if "0" (initial value) is set in Pr. 77
Parameter write selection.
Func-
Parameter
tion
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency 0 to 120Hz
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
40
RUN key rotation direction selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
17
Name
Setting Range
0 to 30%
0 to 120Hz
0 to 120Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600s
0 to 3600s
0 to 500A
0 to 10s
0 to 30%
0 to 60Hz
0 to 3
0 to 400Hz
0 to 3600s
0, 2, 4
120 to 400Hz
0 to 1000V, 8888, 9999
1 to 400Hz
0 to 200%
0 to 200%, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 1, 2
0, 1, 2
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 0.01 to 9998
0, 1
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
Minimum
Initial
Customer
Setting
Value
Increments
0.1%
6/4/3%
∗1
0.01Hz
120Hz
0.01Hz
0Hz
0.01Hz
60Hz
0.01Hz
60Hz
0.01Hz
30Hz
0.01Hz
10Hz
0.1s
5/10s
∗2
0.1s
5/10s
∗2
Rated
0.01A
inverter
current
0.01Hz
3Hz
0.1s
0.5s
0.1%
6/4%
∗3
0.01Hz
0.5Hz
1
0
0.01Hz
5Hz
0.1s
0.5s
1
0
0.01Hz
120Hz
0.1V
9999
0.01Hz
60Hz
0.1%
150%
0.1%
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
1
0
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.001
0
1
0
0.1%
10%
0.01Hz
6Hz
0.01Hz
9999
Setting

Hide quick links:

Advertisement

Table of Contents
loading