QuickSpecs
Technical Specifications
System Inlet
Temperature
Relative
Humidity
(non-condensing) Non-operating
Altitude
Acoustic Noise
Standard
10° to 35°C (50° to 95°F) at sea level with an altitude derating
Operating Support
of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea
level to a maximum of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The
upper limit and rate of change may be limited by the type and
number of options installed. System performance during
standard operating support may be reduced if operating with a
fan fault or above 30°C (86°F).
Extended Ambient
For approved hardware configurations, the supported system
Operating Support
inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35°
to 40°C (95° to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed at the URL:
http://www.hp.com/servers/Ashrae
For approved hardware configurations, the supported system
inlet range is extended to be: 40° to 45°C (104° to 113°F) at
sea level with an altitude derating of 1.0°C per every 125 m
(1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum
of 3050 m (10,000 ft). The approved hardware configurations
for this system are listed at the URL:
http://www.hp.com/servers/Ashrae
System performance may be reduced if operating in the
extended ambient operating range or with a fan fault.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is
20°C/hr (36°F/hr).
Operating
10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet
bulb temperature, non-condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet
bulb temperature, non-condensing.
Operating
3048 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when the
product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with
ISO 9296 (ECMA 109).
Idle
L WAd
6.8 B
L pAm
51.2
Operating
L WAd
6.9 B
HPE ProLiant DL560 Generation9 (Gen9)
Page 48