INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power at the breaker or
disconnect switch and
tag-out in accordance with
procedures and codes.

VOLTAGE CHECK

i
SURROUNDING

THERMOSTATS

07610-004-37-13-E
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located at the left-front side of the dishmachine. Refer to the data plate
for machine operating requirements, machine voltage, total amperage, and serial number.
Remove the back panel and set aside. This will require removing the screw at the
bottom of the back panel with a phillips screwdriver. Install 3/4" conduit into the pre-
punched holes in the back of the control box. Route power wires and connect to power
block and grounding lug. Install the service wires (L1 and L2 for HT, L1 and N for LT/
LT-H) to the appropriate terminals as they are marked on the terminal block. Install
the grounding wire into the lug provided. It is recommended that "DE-OX" or another
similar anti-oxidation agent be used on all power connections.
Ensure that the "ON/OFF" switch is in the "OFF" position and apply power to
dishmachine. Check the incoming power at the terminal block and ensure it
corresponds with the voltage listed on the data plate. If not, contact a qualified service
agency to examine the problem. Do not run dishmachine if voltage is too high or too
low. Shut-off the service breaker and advise all proper personnel of the location of
the breaker and any problems. Replace the control box cover and tighten-down the
screws.
This is a commercial dishmachine and reaches temperatures that can exceed
those generated by a residential machine. Surrounding countertops, cabinets, flooring
AREA
material, and subfloor material must be designed and/or selected with these higher
temperatures in mind.
NOTE: Any damage to surrounding area that is caused by heat and/or moisture
NOTICE
to materials that are not recommended for higher temperatures will not be covered
under warranty or by the manufacturer.
The thermostats on this dishmachine have been set at the factory. They should only
be adjusted by an authorized service agent.
HT
GRND
L1
L2
DETAIL A
SCALE 1 / 3
INSTRUCTIONS
LT/LT-H
GRND
L1
N
DETAIL A
SCALE 1 / 3