Tcon/Vcom Alignment; Overview Matrix Correction Table - Philips 32PFL8605H/12 Service Manual

Hide thumbs Also See for 32PFL8605H/12:
Table of Contents

Advertisement

EN 46
6.
Q551.1E LA
Table 6-3 White D alignment values - LED - Minolta CS-200
Value
Cool (11000K)
x
0.276
y
0.282
If you do not have a colour analyser, you can use the default
values. This is the next best solution. The default values are
average values coming from production.
Select a COLOUR TEMPERATURE (e.g. COOL,
NORMAL, or WARM).
Set the RED, GREEN and BLUE default values according
to the values in
Table
When finished press OK on the RC, then press STORE (in
the SAM root menu) to store the aligned values to the NVM.
Restore the initial picture settings after the alignments.
Table 6-4 White tone default setting 32" (Monet)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-5 White tone default setting 32" (Rubens)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-6 White tone default setting 37" (Monet)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-7 White tone default setting 40" (Monet)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-8 White tone default setting 40" (Rubens)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-9 White tone default setting 46" (Monet)
White Tone
Colour Temp
Normal
Cool
Warm
2010-Oct-01
Alignments
Normal (9000K)
Warm (6500K)
0.287
0.313
0.296
0.329
6-4.
e.g. 32PFL8605x/xx
R
G
B
127
124
99
126
126
115
127
115
56
e,g, 32PFL9705x/xx
R
G
B
127
112
103
125
121
124
127
107
59
e.g. 37PFL8605x/xx
R
G
B
127
98
99
122
111
127
127
101
66
e.g. 40PFL8605x/xx
R
G
B
127
118
88
126
126
106
127
109
54
e.g. 40PFL9705x/xx
R
G
B
127
111
117
121
117
127
127
109
78
e.g. 46PFL8605x/xx
R
G
B
127
122
100
121
127
115
127
115
67
Table 6-10 White tone default setting 46" (Rubens)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-11 White tone default setting 52" (Monet)
White Tone
Colour Temp
Normal
Cool
Warm
Table 6-12 White tone default setting 58" (Rubens 21:9)
White Tone
Colour Temp
Normal
Cool
Warm
6.3.2
Ambilight
Every ambient light module is aligned by a matrix and by the
brightness. After replacement of a module, the brightness/color
must be aligned with the other modules:
1. Go to SAM.
2. Select "Alignments".
3. Select "Ambilight". A white test pattern shall be displayed
by the ambilight modules.
4. Select the number of the module that have to be aligned.
Module 1 is the first one which will come across according
the wiring path, starting at the small signal panel,
proceeding towards the ambient light modules.The first
module will be attached to the next module 2. Module
number 2 to number 3 etc..as follows the way to define the
ambilight module numbering.
5. Align the brightness compaired with the neighbouring
modules. The brightness is automatically stored.
6. Select one of 10 matrixes which color matches most with
the neighbouring modules, "matrix 0" is the factory
alignment and can always be retrieved. (see table

Overview matrix correction table

7. The alignment is stored automatically.
Table 6-13 Overview matrix correction table
Matrix #
Matrix 0
Matrix 1
Matrix 2
Matrix 3
Matrix 4
Matrix 5
Matrix 6
Matrix 7
Matrix 8
Matrix 9
6.3.3

TCON/VCOM alignment

Sets with forward integration have the TCON on SSB. The
alignment of this TCON is stored in the SSB, and is related to
the used display. When an SSB or a display is replaced, a new
value must be entered.
A default value (see table below) is copied from the display file
(after entering the correct display code) and is shown in the
SAM menu. But on top of this, the default value can be
overruled manually via the menu item "TCON alignment".
back to
div. table
e.g. 46PFL9705x/xx
R
G
127
119
114
117
127
112
e.g. 52PFL8605x/xx
R
G
t.b.d.
t.b.d.
t.b.d.
t.b.d.
t.b.d.
t.b.d.
e.g. 58PFL9955x/xx
R
G
127
109
126
109
127
104
fR
fG
1
1
1
0.95
0.95
1
0.95
0.95
0.95
1
1
0.95
1
1
1
0.97
0.97
0.95
0.95
0.97
B
112
127
87
B
t.b.d.
t.b.d.
t.b.d.
B
115
127
83
"6-13
fB
1
0.95
0.95
1
1
1
0.95
0.95
1
1