Alignments; General Alignment Conditions; Software Alignments; White Point - Philips 32PFL8605H/12 Service Manual

Hide thumbs Also See for 32PFL8605H/12:
Table of Contents

Advertisement

6. Alignments

Index of this chapter:

6.1 General Alignment Conditions

6.2 Hardware Alignments

6.3 Software Alignments

6.4 Option Settings
6.5 Reset of Repaired SSB
6.6 Total Overview SAM modes
6.1
General Alignment Conditions
Perform all electrical adjustments under the following
conditions:
Power supply voltage (depends on region):
AP-NTSC: 120 VAC or 230 V
AP-PAL-multi: 120 - 230 V
EU: 230 V
/ 50 Hz (± 10%).
AC
LATAM-NTSC: 120 - 230 V
US: 120 V
/ 60 Hz (± 10%).
AC
Connect the set to the mains via an isolation transformer
with low internal resistance.
Allow the set to warm up for approximately 15 minutes.
Measure voltages and waveforms in relation to correct
ground (e.g. measure audio signals in relation to
AUDIO_GND).
Caution: It is not allowed to use heat sinks as ground.
Test probe: Ri > 10 MΩ, Ci < 20 pF.
Use an isolated trimmer/screwdriver to perform
alignments.
6.1.1
Alignment Sequence
First, set the correct options:
In SAM, select "Option numbers".
Fill in the option settings for "Group 1" and "Group 2"
according to the set sticker (see also paragraph
Option
Settings).
Press OK on the remote control before the cursor is
moved to the left.
In submenu "Option numbers" select "Store" and press
OK on the RC.
OR:
In main menu, select "Store" again and press OK on
the RC.
Switch the set to Stand-by.
Warming up (>15 minutes).
6.2
Hardware Alignments
Not applicable.
6.3
Software Alignments
Put the set in SAM mode (see Chapter
Codes, and Fault
Finding). The SAM menu will now appear on
the screen. Select ALIGNMENTS and go to one of the sub
menus. The alignments are explained below.
The following items can be aligned:

White point

Ambilight
TCON Alignment
Reset TCON Alignment.
To store the data:
Press OK on the RC before the cursor is moved to the
left
In main menu select "Store" and press OK on the RC
Switch the set to stand-by mode.
/ 50 Hz (± 10%).
AC
/ 50 Hz (± 10%).
AC
/ 50 Hz (± 10%).
AC
6.4
5. Service Modes, Error
back to
div. table
Alignments
Q551.1E LA
For the next alignments, supply the following test signals via a
video generator to the RF input:
EU/AP-PAL models: a PAL B/G TV-signal with a signal
strength of at least 1 mV and a frequency of 475.25 MHz
US/AP-NTSC models: an NTSC M/N TV-signal with a
signal strength of at least 1 mV and a frequency of 61.25
MHz (channel 3).
LATAM models: an NTSC M TV-signal with a signal
strength of at least 1 mV and a frequency of 61.25 MHz
(channel 3).
6.3.1
White Point
Choose "TV menu", "Setup", "More TV Settings" and then
"Picture" and set picture settings as follows:
Picture Setting
Contrast
Brightness
Colour
Light Sensor
Picture format
In menu "Picture", choose "Pixel Plus HD" and set picture
settings as follows:
Picture Setting
Dynamic Contrast
Dynamic Backlight
Colour Enhancement
Gamma
Go to the SAM and select "Alignments"-> "White point".
White point alignment LCD screens:
Use a 90% white screen to the HDMI input and set the
following values:
"Colour temperature": "Normal".
All "White point" values to: "127".
In case you have a colour analyser:
Measure, in a dark environment, with a calibrated
contactless colour analyser (Minolta CA-210 or Minolta
CS-200) in the centre of the screen.
Adjust the correct x, y coordinates (while holding one of the
White point registers R, G or B on 127) by means of
decreasing the value of one or two other white points to the
correct x, y coordinates (see Table
values CCFL backlight
values - LED - Minolta CA-210
values - LED - Minolta
± 0.002.
Repeat this step for the other colour temperatures that
need to be aligned.
When finished press OK on the RC and then press STORE
(in the SAM root menu) to store the aligned values to the
NVM.
Restore the initial picture settings after the alignments.
Table 6-1 White D alignment values CCFL backlight panels
Value
Cool (11000K)
x
0.276
y
0.282
Table 6-2 White D alignment values - LED - Minolta CA-210
Value
Cool (9420K)
x
0.282
y
0.298
6.
EN 45
100
50
0
Off
Unscaled
Off
Off
Off
0
6-1 White D alignment
panels,
6-2 White D alignment
or
6-3 White D alignment
CS-200). Tolerance: dx: ± 0.002, dy:
Normal (9000K)
Warm (6500K)
0.287
0.313
0.296
0.329
Normal (8120K)
Warm (6080K)
0.292
0.320
0.311
0.345
2010-Oct-01