Optical Parts Disassembly
2. Polarized glass-in assy removal
(M.5x6)x1
*Note on handling the polarized glass
B-Polarized glass-in is very sensitive parts.
Never touch or wipe the surface. Grab the
mounting base when handling the polarized
glass assy. When removing the dust on the
surface, use a commercial (inert gas) air spray
to remove them. Never use organic solvents.

3. Projection lens removal

Note: The optical unit should be removed from the cabinet bottom before
removing the projection lens.
(M.5x8)x4
Fig.3
Polarized glass-in assy
Fig.2
Projection lens
Note on mounting the Polarized glass-in assy
When mounting the R-Polarized glass-in assy and
B-Polarized glass-in assy, make sure that mounting position
of the holder should be center.
-1-
Polarized glass-in
*Polarized glass is not removed
from the mounting base.
Optical unit