INTRODUCTION 4.1 SCOPE This air stapler is designed to insert steel staples. Any other use is forbidden. 4.2 SPECIFICATION Stock no..........................14608 Part no......................... SFASK1025 Operating Air Pressure..................60-100PSI (4-7Bar) Max. Safety Working Pressure..................115PSI (8Bar) Min. Air Hose Size ....................... "...
HEALTH & SAFETY INFORMATION 5.1 GENERAL SAFETY INSTRUCTIONS FOR POWER TOOL USE When using any type of power tool there are steps that should be taken to make sure that you, as the user, remain safe. Common sense and a respect for the tool will help reduce the risk of injury. Read the instruction manual fully.
Page 7
HEALTH & SAFETY INFORMATION Move the machine as instructed. If the machine is hand held, do not carry it by the air line. If the product is heavy; employ a second or third person to help move it safely or use a mechanical device.
HEALTH & SAFETY INFORMATION 5.2 ADDITIONAL SAFETY INSTRUCTIONS FOR AIR STAPLER/NAILER Only those fasteners listed in the operating instructions may be used in the fastener driving tools. Do not use on scaffoldings and ladders. Check prior to each operation that the safety and triggering mechanism is functioning properly and that all nuts and bolts are tight.
HEALTH & SAFETY INFORMATION 5.3 RESIDUAL RISK Important note: Although the safety instructions and operating manuals for our tools contain extensive instructions of safe working with power tools, every power tool involves a certain residual risk which can not be completely excluded by safety mechanisms. Power tools must therefore always be operated with caution!
Lay the contents out and check them against the parts shown below. If any part is damaged or missing; please contact the Draper Helpline (the telephone number appears on the Title page) and do not attempt to use the product.
Draper range (see you local Draper stockist) which with proper maintenance will ensure a constant supply of dry air and lubricating oil at all times (see illustration below). Always check machine operating pressure before use.
To connect the air ratchet to an air line, a ¼"BSP male thread whip hose* will be required. Wind a length of PTFE tape** around the thread before securing the hose in place. The connection must be tight for an airtight union. * Draper Stock No.54438. ** Draper Stock No.63389.
10. OPERATION AND USE 10.1 LOADING THE STAPLER - FIGS. 3 - 6 FIG.3 NOTE: Always disconnect the tool from the air supply before any adjustment or maintenance is carried out. Press the magazine latch and gently slide the magazine back.
10. OPERATION AND USE 10.2 SAFETY LATCH - FIGS. 7 - 8 FIG.7 This tool is fitted with a safety latch on the trigger, which should be engaged when the tool is NOT in use. To operate the air stapler, slide the safety latch to one side, then pull the trigger to fire.
10. OPERATION AND USE 10.3 CLEARING A JAM - FIGS. 9 - 10 Note: Always disconnect the tool from the air supply before any adjustment or maintenance is carried out. FASTENER JAMMED INSIDE MAGAZINE Open the magazine latch and pull open the magazine. Remove the fastener that is causing the obstruction using long nose pliers.
11. MAINTENANCE 11.1 EVERY-DAY MAINTENANCE CHECKS Before connection to the air supply: • Drain the compressor reservoir of condensate. • Drain the air lines of condensate. • Drain the combined separator filter, regulator, water trap. • Fill up the combined separator filter, regulator, lubricant reservoir with approved air tool oil.
• ‘O’ ring throttle valve dislodged • Replace ‘O’ ring or return to from seat inlet valve. service centre. We recommend the use of Draper Air Tool Oil: 250ml = Stock No.34679, 500ml = Stock No.34681, 1Litre = Stock No.34682.