TO REMOVE:
1. Remove the front cover (See page 11).
2. Remove the 2 setscrews (A) and remove the A-board.
3. Remove the setscrew (B) and slide the upper shaft shield plate to the left.
4. Remove the 2 setscrew (C) and remove the upper shaft sensor (P-board).
TO ATTACH:
1. To attach the upper shaft sensor, follow the above procedure in reverse.
Note
Check the "ZIGZAG SYNCHRONIZATION" (See page 19) after attaching the upper shaft shield
plate.

UPPER SHAFT SENSOR