Telephone Line Fail – A telephone line fault registers when the system detects that the
telephone line is disconnected from the control panel. Your installer must program the system
for this feature to operate.
Power Supply Fail – This fault occurs when AUX power supplies fails, +12V power fails, or
SDI2 Bus power fails. Contact your installer as soon as this fault displays.
Onboard Tamper – This fault occurs when the system detects the control panel is tampered.
RF Repeater Fail – The RF repeater 1 to 8 fault registers once the system detects that the
wireless repeater is disconnected, tampered or jammed.
2 RF Low Battery
This fault occurs when any of the RF wireless devices report a low battery condition to the
control panel. While in Fault Analysis Mode, press the [2] key until two beeps sound. This
displays the zone reporting the RF Low Battery fault.
3 Zone Tamper Fail
This fault occurs when any zone with tamper becomes an open or short circuit. Press the [3]
key until two beeps sound. This displays the zone reporting the tamper fail fault.
4 Sensor Watch Fault
A sensor watch fault registers because one or more detection devices failed to detect any
movement during the disarmed state for the time period programmed by your installer. The
fault clears once the zone in question detects movement and resets. Press the [4] key until
two beeps sound. This displays the zone reporting the sensor watch fault.
5 RF Sensor Missing
An RF sensor missing fault registers because one or more RF detection devices fails to
communicate to the RF radio receiver for the time period programmed by your installer. The
fault clears once the RF device in question successfully transmits to the RF radio receiver.
Press the [5] key until two beeps sound. This displays the RF detection device reporting the
RF sensor watch fault.
6 Communication Fail
A communication fail registers when the control panel fails to communicate with the receiving
party (such as a monitoring company, mobile phone). The communication fault clears once the
control panel successfully reports to the receiving party.
A communication fail also registers when network module is disconnected or tampered.
To determine which receiver or module failed to communicate, press the [6] key.
7 Output and Codepad Fail
The output fault registers when the output expander B308 is disconnected or tampered.
The codepad fault registers when any codepad is tampered or disconnected from the control
panel.
To determine which fault occurred, press the [7] key.
8 Keyfob Low Battery
This fault occurs when any of the RF keyfobs report a low battery condition to the control
panel. To determine which keyfob failed, press the [8] key. Only keyfob 1 to 16 faults display
on the codepad through zone indicator 1 to 16.
Bosch Security Systems, Inc.