Regular checks

8.1

Checking operation

During normal operation, the alarm indicator is hidden to show that everything is OK. When an alarm is triggered, the alarm indicator
flashes and at the same time an error code is shown in the display.
Error code
Description
00
Communication failure
01
Return water sensor (T9) failure
02
Supply water sensor (T8) failure
03
Water flow switch protection
04
Phase sequence error (only applies to 3-phase models)
05
Excessive temperature difference protection of supply and return water
06
Internal electrical heater overheat protection
07
Condenser overheat protection
08
Hot water tank sensor (T3) failure
09
Buffer tank sensor (T2) failure
10
High pressure protection
11
Low pressure protection
12
Supply water temperature too high
13
Supply water temperature too low
14
Return gas temperature sensor (T5) failure
15
Exhaust gas temperature sensor (T4) failure
16
Exhaust gas temperature overheat protection
17
Null
18
Frost protection, step 2 (non-fault)
19
Frost protection, step 1 (non-fault)
20
Air temperature sensor (T1) failure
21
Heating coil sensor (T7) failure
22
Cooling coil sensor (T6) failure
23
Exceeded operation range warning (non-fault)
8.2

Check the water level in the heating circuit

The line pressure of the installation must be checked once a month.
The external manometer (if available) must show a value between 1-1.5 bar. If the value is below 0.8 bar, when the water in the heating
system is cold, the water must be topped up (applies in the event of an empty expansion tank).
Ordinary tap water can be used when topping up the heating system. In certain exceptional cases, the water quality may be poor (for
example very hard water) and is not suitable for filling the heating system. If unsure, contact your installer.
The closed expansion tank contains an air filled bladder that absorbs variations in the heating system's vol-
N
ume. Under no circumstances may it be drained of air.
Danfoss Heating Solutions
DHP-AT
Check the alarm indicator regularly to ensure that the appliance is work-
ing correctly. In the event of an alarm the heat pump will, if possible, sup-
ply heating to the house, primarily with the compressor, secondarily with
the internal electrical heater.
The hot water production will stop to indicate that something notewor-
thy has occurred.