Installation - Whirlpool HGF 9.5S AB X/HA Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35

Installation

of this manual.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution! Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust
(for ducted units)
Connect the hood to a duct and wall exhaust hole of a
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
! Use the shortest duct required to achieve the purpose.
! Use a duct with as few bends as possible
! Avoid suddenly changing the diameter of the duct.
! The duct must have as smooth an inner surface as
possible.
! The duct must be made of regulatory material.
!
fumes from other equipment (boilers, GLASSs, stoves, etc.).
! Observe the instructions of the competent authorities in
relation to the air exhaust. The air being exhausted may not
be exhausted into a wall cavity unless the cavity in question
! Equip the room with air intakes to prevent the hood creating
suction pressure in the interior (this must not exceed 0.04
mbar).
! The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
!
Note: If supplied with the hood, the accessory active
Instructions for transforming the hood from the ducted to the
Ducted version
The diameter of the exhaust tube must be equal to that of
Caution! The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
Filter version
version of the hood requires installation of an accessory
outlet slots uppermost.
Technical data
Height
Model
(cm)
GLASS 60cm
GLASS 90cm
Model code
Bulb (V)
Halogen
Model code
Bulb (V)
Halogen
Model code
Bulb (V)
Halogen
The hoods are conforming to the following EC
Directives:
dia. of
Width
Depth
exhaust tube
(cm)
(cm)
(cm)
59.8
50
15/12
89.9
50
15/12
Bulb draw (W) Total draw (W)
2 x 40
185
Bulb draw (W) Total draw (W)
2 x 40
290
Bulb draw (W) Total draw (W)
2 x 40
150
35
GB

Advertisement

Table of Contents
loading

Table of Contents