(c)
To remove a sheet just entering the fuser (c), separate the trailing edge of the
sheet from the belt, push the fuser pressure release lever (d) towards the front
and down to release the fuser's grip on the sheet, and withdraw the sheet through
the drum cavity area. Then allow the pressure release lever to rise again.
NOTE
If the sheet is well advanced into the fuser (only a short length is still visible),
do not attempt to pull it back.
(d)
To remove a sheet in the fuser, push the two retaining levers (e) towards the rear
of the printer to release the fuser. Withdraw the fuser unit using the handle (f).
(e)
Press release lever (g) and pull the trapped paper from the fuser.
(f)
Replace fuser unit into the machine and move locking levers (e) toward the rear
of the machine.
e
f
e
e
Troubleshooting > 85
d
g