Electrical Adjustment
Grp /
Item
No.
0
Filter 1st Cartridge Scroll Factor 1
1
Filter 1st Cartridge Scroll Factor 2
2
Filter 1st Cartridge Scroll Factor 3
3
Filter 1st Cartridge Scroll Factor 4
4
Filter 1st Cartridge Scroll Factor 5
5
Filter 1st Cartridge Scroll Factor 6
6
Filter 1st Cartridge Scroll Factor 7
7
Filter 1st Cartridge Scroll Factor 8
8
Filter 1st Cartridge Scroll Factor 9
9
Filter 1st Cartridge Scroll Factor 10
10
Filter 2nd Cartridge Scroll Factor 1
11
Filter 2nd Cartridge Scroll Factor 2
12
Filter 2nd Cartridge Scroll Factor 3
13
Filter 2nd Cartridge Scroll Factor 4
14
Filter 2nd Cartridge Scroll Factor 5
15
Filter 2nd Cartridge Scroll Factor 6
16
Filter 2nd Cartridge Scroll Factor 7
17
Filter 2nd Cartridge Scroll Factor 8
18
Filter 2nd Cartridge Scroll Factor 9
19
Filter 2nd Cartridge Scroll Factor 10
20
Filter 3rd Cartridge Scroll Factor 1
21
Filter 3rd Cartridge Scroll Factor 2
22
Filter 3rd Cartridge Scroll Factor 3
23
Filter 3rd Cartridge Scroll Factor 4
24
Filter 3rd Cartridge Scroll Factor 5
25
Filter 3rd Cartridge Scroll Factor 6
26
Filter 3rd Cartridge Scroll Factor 7
27
Filter 3rd Cartridge Scroll Factor 8
28
Filter 3rd Cartridge Scroll Factor 9
29
Filter 3rd Cartridge Scroll Factor 10
249
Pressure Sensor
0
Pressure Monitor
1
Pressure Moniture
2
Press Offset
3
Press Calib Effective Diff
4
Press Sensor Calibration Log
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Min Adjust (DAC)
11
Fan 6 Max Adjust (DAC)
12
Fan 7 Min Adjust (DAC)
13
Fan 7 Max Adjust (DAC)
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6 Manual Voltage
9
Fan7 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
Function
1st Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
2nd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
Pressure Value (Original) [ADC]
Pressure Value (Compensated)[ADC]
Offset Value
Effective Range of Calibration
Calibration LOg
0: Excuted and Adquate Offset Value
10:Out of Range (Mini)
20: Out of Range (Max)
99: Not executed
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-1023 - 1023
0 - 1023
-
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-6
0-1
0-145
0-145
0-145
0-145
0-145
0-145
0-145
-
-
-
-55-
Initial
Note
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
-
-
0
1023
99
* Fan voltage adj.
84
237
83
240
40
244
40
230
41
232
43
233
39
229
0
0
100
100
100
100
100
100
100
-
-
-