Electrical Adjustment
Grp /
Item
No.
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
8
Enable Close Cmd
9
Speed Control
10
Shutter Management Upper Time
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
3
Air Inlet Check Enable
4
Time Limit Auto Scroll Enble
5
Clog Auto Cooling Enable
6
Scroll Fail Auto Cooling Enable
7
Timer Force Scroll Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
6
Flow Ideal Data 7
7
Flow Ideal Data 8
242
Flow Calib. Fan Volt
0
Flow Calib Fan Volt 1
1
Flow Calib Fan Volt 2
2
Flow Calib Fan Volt 3
3
Flow Calib Fan Volt 4
4
Flow Calib Fan Volt 5
5
Flow Calib Fan Volt 6
6
Flow Calib Fan Volt 7
7
Flow Calib Fan Volt 8
243
Flow Calib Effective Difference
0
Flow Calib Effective Diff 1
1
Flow Calib Effective Diff 2
2
Flow Calib Effective Diff 3
3
Flow Calib Effective Diff 4
4
Flow Calib Effective Diff 5
5
Flow Calib Effective Diff 6
6
Flow Calib Effective Diff 7
7
Flow Calib Effective Diff 8
244
Flow Clog Threshold
0
Flow Clog Threshold 1
1
Flow Clog Threshold 2
2
Flow Clog Threshold 3
3
Flow Clog Threshold 4
4
Flow Clog Threshold 5
5
Flow Clog Threshold 6
6
Flow Clog Threshold 7
7
Flow Clog Threshold 8
10
Flow Inlet Err Threshold1
Function
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Close Command 0: Disable, 1: Enable
Shutter Speed
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
Air inlet Error Detection by Wind Sensor (0: Disable, 1: Enable)
Auto Scroll (0: Disable, 1: Enable)
Auto Cooling at Clog (0: Disable, 1: Enable)
Auto Cooling at Scroll Error (0: Disable, 1: Enable)
Filter Timer (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Fan Voltage No.1 [x10 V]
Flow Sensor Calibration Fan Voltage No.2 [x10 V]
Flow Sensor Calibration Fan Voltage No.3 [x10 V]
Flow Sensor Calibration Fan Voltage No.4 [x10 V]
Flow Sensor Calibration Fan Voltage No.5 [x10 V]
Flow Sensor Calibration Fan Voltage No.6 [x10 V]
Flow Sensor Calibration Fan Voltage No.7 [x10 V]
Flow Sensor Calibration Fan Voltage No.8 [x10 V]
(Not Memorized)
Flow Sensor Calibration Range Diff No.1 [ADC]
Flow Sensor Calibration Range Diff No.2 [ADC]
Flow Sensor Calibration Range Diff No.3 [ADC]
Flow Sensor Calibration Range Diff No.4 [ADC]
Flow Sensor Calibration Range Diff No.5 [ADC]
Flow Sensor Calibration Range Diff No.6 [ADC]
Flow Sensor Calibration Range Diff No.7 [ADC]
Flow Sensor Calibration Range Diff No.8 [ADC]
(Not Memorized )
Flow Sensor Clogged Threshold No.1[ADC]
Flow Sensor Clogged Threshold No.2[ADC]
Flow Sensor Clogged Threshold No.3[ADC]
Flow Sensor Clogged Threshold No.4[ADC]
Flow Sensor Clogged Threshold No.5[ADC]
Flow Sensor Clogged Threshold No.6[ADC]
Flow Sensor Clogged Threshold No.7[ADC]
Flow Sensor Clogged Threshold No.8[ADC]
Flow Sensor Inlet Err Threshold No.1[ADC]
Range
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 255
180- 999
0 - 1
-
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
-53-
Initial
Note
15000
0
0
0
50
1
0
480
* Wind sensor
0
calibration.
255
Initial: 0 / Shipping: 1
Initial: 0 / Shipping: 1
1
1
1
0
254
265
287
312
333
352
368
383
42
50
60
75
90
105
120
138
300
300
300
300
300
300
300
300
53
72
84
108
131
147
164
179
84