Optical Parts Disassembly
2. Polarized Glass-in removal
1. Remove 2 screws-E (M2.5x6) each on the Polarized glass assy and remove
the stoppers, and pull the Polarized Glass assy upward.
Polarized glass assy
Point marker
Polarized glass-in (B) *
* N ote on handling the polarized glasses
Polarized glass-in (B) and (G) are very sensitive parts. Never touch or
wipe the both surfaces. Grab the edge of the glass by new gloves when
handling the polarized glass. When removing the dust on the surface,
use a commercial (inert gas) air spray to remove them. Never use organic
solvents.
E
E
D
Point marker
Film attached side
comes to this side
-28-
D
D
E
E
Polarized glass-in (R)
Point marker
Polarized glass-in (G) *
E
E

Hide quick links: