Electrical Adjustment
Grp /
Item
No.
210
Lamp Control
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL1
3
DIMMER_CTRL_LEVEL2
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
211
Lamp Iris
0
Mode
1
Error Detect Enable
2
Open Position Offset
3
Speed adjust
4
Muaul Position Adjust
5
APL Threshold Min
6
APL Threshold Max
10
Close Limit Dimmer 0
11
Close Limit Dimmer 1
12
Close Limit Dimmer 2
13
Close Limit Dimmer 3
14
Close Limit Dimmer 4
15
Close Limit Dimmer 5
16
Close Limit Dimmer 6
17
Close Limit Dimmer 7
18
Close Limit Dimmer 8
19
Close Limit Dimmer 9
20
Close Limit Dimmer 10
21
Close Limit Dimmer 11
22
Close Limit Dimmer 12
23
Close Limit Dimmer 13
24
Close Limit Dimmer 14
25
Close Limit Dimmer 15
26
Open Limit
30
Update Interval
40
Multi Window Mode Enable
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
Function
0:Auto 1:Manual
Lamp Power Manual Control (DIMMER_CTRL_LEVEL 0(Dark)-
15(Bright))
Y Level1 Data for Dimmer
Y Level2 Data for Dimmer
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Iris Mode Setting
0: Setting by Menu according to APL
1: Manually setting(Menu setting disable)
2:Setting to OFF
3: Life Mode Test
Iris Error Detect Enable
0: Disable 1:Enable
Open Position Offset adjust
Speed adjust
Manual Postion adjust for Iris OFF
(Available when S211-0 is set to 0)
APL Threshold Parameter (Min)
APL Threshold Parameter (Max)
Close Limit, Dimmer Level 0
Close Limit, Dimmer Level 1
Close Limit, Dimmer Level 2
Close Limit, Dimmer Level 3
Close Limit, Dimmer Level 4
Close Limit, Dimmer Level 5
Close Limit, Dimmer Level 6
Close Limit, Dimmer Level 7
Close Limit, Dimmer Level 8
Close Limit, Dimmer Level 9
Close Limit, Dimmer Level 10
Close Limit, Dimmer Level 11
Close Limit, Dimmer Level 12
Close Limit, Dimmer Level 13
Close Limit, Dimmer Level 14
Close Limit, Dimmer Level 15
Open Limit,,Dimmer Level 0-15
Tim of update interval (Unit: ms)
Iris OFF while 2 pictures
0: OFF, 1: setting according to ImageMode
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Range
0 - 1
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 3
0 - 1
-511 - 511
1 - 1023
0 - 1023
0 - 255
0 - 255
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1
0 - 32767
:
0 - 32767
0 - 10
0 - 1
0 - 32767
-52-
Initial
Note
0
0
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
-
0
1
-12
4/1(AV/PC)
0
0/4(AV/PC)
128/9(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
560/728(AV/PC)
0/0(AV/PC)
8/18(AV/PC)
1
0
:
0
0
Initial: 1 / Shipping: 0