Eiki LC-WUL100 Service Manual page 54

Hide thumbs Also See for LC-WUL100:
Table of Contents

Advertisement

Electrical Adjustment
Grp /
Item
No.
11
Flow Inlet Err Threshold2
12
Flow Inlet Err Threshold3
13
Flow Inlet Err Threshold4
14
Flow Inlet Err Threshold5
15
Flow Inlet Err Threshold6
16
Flow Inlet Err Threshold7
17
Flow Inlet Err Threshold8
245
Filter Roll
0
Take Up Bend
1
Take Up Times
2
Take Up Time Reset
3
Scroll Counter Reset Time
4
Scroll Information Cartridge No
246
Flow Clog Monitor
0
Real Flow Data
1
Ideal Flow Data
2
Flow Difference Data
3
Clog Detect Flow Difference Data
4
Warn Detect Flow Difference Data
5
Press Add Data
6
Filter Scroll Timer
7
Air Inlet Err Difference Data
247
Filter Scroll Time
0
Filter 1st Cartridge Scroll Time 1
1
Filter 1st Cartridge Scroll Time 2
2
Filter 1st Cartridge Scroll Time 3
3
Filter 1st Cartridge Scroll Time 4
4
Filter 1st Cartridge Scroll Time 5
5
Filter 1st Cartridge Scroll Time 6
6
Filter 1st Cartridge Scroll Time 7
7
Filter 1st Cartridge Scroll Time 8
8
Filter 1st Cartridge Scroll Time 9
9
Filter 1st Cartridge Scroll Time 10
10
Filter 2nd Cartridge Scroll Time 1
11
Filter 2nd Cartridge Scroll Time 2
12
Filter 2nd Cartridge Scroll Time 3
13
Filter 2nd Cartridge Scroll Time 4
14
Filter 2nd Cartridge Scroll Time 5
15
Filter 2nd Cartridge Scroll Time 6
16
Filter 2nd Cartridge Scroll Time 7
17
Filter 2nd Cartridge Scroll Time 8
18
Filter 2nd Cartridge Scroll Time 9
19
Filter 2nd Cartridge Scroll Time 10
20
Filter 3rd Cartridge Scroll Time 1
21
Filter 3rd Cartridge Scroll Time 2
22
Filter 3rd Cartridge Scroll Time 3
23
Filter 3rd Cartridge Scroll Time 4
24
Filter 3rd Cartridge Scroll Time 5
25
Filter 3rd Cartridge Scroll Time 6
26
Filter 3rd Cartridge Scroll Time 7
27
Filter 3rd Cartridge Scroll Time 8
28
Filter 3rd Cartridge Scroll Time 9
29
Filter 3rd Cartridge Scroll Time 10
248
Filter Scroll Factor
Function
Flow Sensor Inlet Err Threshold No.2[ADC]
Flow Sensor Inlet Err Threshold No.3[ADC]
Flow Sensor Inlet Err Threshold No.4[ADC]
Flow Sensor Inlet Err Threshold No.5[ADC]
Flow Sensor Inlet Err Threshold No.6[ADC]
Flow Sensor Inlet Err Threshold No.7[ADC]
Flow Sensor Inlet Err Threshold No.8[ADC]
Remove Filter Flexure Starts when the Value is set to 1.
Remaining Times of Filter Scroll (Read only)
Filter Scroll Times Reset
Resets Remaining Scroll Times when the Value is set to 10.
Scroll Counter Reset Times (Read only)
(Read only)
Real Flow Data [ADC] (Read only)
Theory Flow Data (Read only)
Flow Difference Data [ADC] (Read only)
Difference Data to judge the Filter Clogged [ADC] (Read only)
Difference Data to judge the Filter Clogged Warning [ADC] (Read
only)
Add Data by Air Pressure (Read only)
Timer for Filter Scroll [hour] (Read only)
Difference Data to judge the Inlet Error [ADC] (Read only)
(Read only)
1st Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
2nd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
3rd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
(Read only)
Range
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1
-
0 - 10
0 - 255
0 - 2
0 - 1023
0 - 1023
-1023 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 32767
0 - 1023
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
0 - 32767
-54-
Initial
Note
112
139
181
222
247
269
291
0
-
0
-
0
-
-
-
-
-
-
-
-
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-wul100l

Table of Contents