Eiki LC-WUL100 Service Manual page 25

Hide thumbs Also See for LC-WUL100:
Table of Contents

Advertisement

Mechanical Disassembly
10. Filter Assy removal
1. Remove the Filter Cover by pulling it outside.
2. Remove 4 screws-A (T3x8) and 1 screw-B (M3x8) and pull the Filter Box
assy upward off.
a
Filter box assy
11. Fans (FN908, FN909, FN910) removal
1. Remove 3 screws-A (T3x15), 1 screw-B (T3x8) and unhook 2 hooks and
remove the Duct Panel Top.
2. Remove 3 screws-C (T3x8) to take the Duct PBS off.
3. Remove 3 screws-D (T3x12) and 3 screws-E (T3x8) to take the Duct Fans
assy off.
Duct panel top
C
C
C
Duct PBS
a
a
a
B
a
a
B
a
Hook
D
D D
e
e
e
Duct fan assy
Filter cover
T3x8
T3x8
T3x8
T3x8
FN909
FN910
-25-
(T3x8)x2
AMF
Filter
sensor
motor
board
(M901)
T3x8
T3x8
Filter
switch
(SW1891)
(T3x8)x3
T3x12
T3x12
T3x12
FN908
Sensor A
board
T3x8