Circuit Adjustments; Adjustments With Commander - Sony KP-EF41ME3 Service Manual

Table of Contents

Advertisement

KP-EF41ME3/MN3/SN3, EF48MN3/SN3

5-1. ADJUSTMENTS WITH COMMANDER

Service adjustments are made with the RM-871 that comes with
this unit.
Entering service mode
With the unit on standby
+
5
Á
The operation sequence puts the unit into service mode.
PIP
TEXT
POWER
BASSO
RM-871

CIRCUIT ADJUSTMENTS

GAME
A/B
1
2
3
4
5
6
7
8
9
0
-/--
MENU
PIP PROGR
ENTER
PROGR
INDEX
PROGR
RM-871
SECTION 5
1, 4
3, 6
MUTING
0
7, 0
8, 0
5, 0
, 0
+
The screen display is :
Adjstment item
Item number
00
VSH
XXX
V2
SOFTWARE VERSION
OEM CODE
– 30 –
Select the adjustment item.
Raise/lower the data value.
Writes.
Executes the writing.
All the data becomes the values in memory.
All user control goes to the standard state.
Service data initialization (Be sure not to use
usually.)
Write 50Hz adjustment data to 60Hz, or vice
versa. (not to use 2, 0 .)
DATA
Mode
1F
SERVICE
50
Depends on the signals
PAL, SECAM : 50
1C
00 00 00
20
NTSC
H SYNC COUNTER
: 60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp-ef41sn3Kp-ef41mn3Kp-ef48mn3Kp-ef48sn3

Table of Contents