Specifications - Stihl FSA 65 Instruction Manual

Hide thumbs Also See for FSA 65:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 32

Specifications

Battery
Model:
Lithium-ion
The power tool can be operated with
STIHL type AP batteries.
Power tool running time depends on the
stored energy of the battery (e.g. 80 Wh
with AP 80 or 160 Wh with AP 160).
Charger
AL 100
Mains voltage:
220 - 240 V
Rated current:
0.6 A
Frequency:
50 Hz
Power consumption:
75 W
Charging current:
1.6 A
Insulation:
II, E (double
insulated)
AL 300
Mains voltage:
220 - 240 V
Rated current:
2.6 A
Frequency:
50 Hz
Power consumption:
320 W
Charging current:
6.5 A
Insulation:
II, E (double
insulated)
FSA 65, FSA 85
Charging Times
AL 100
with AP 80:
– up to 80% capacity:
70 min
– up to 100% capacity: 100 min
with AP 120:
– up to 80% capacity:
120 min
– up to 100% capacity: 140 min
with AP 160:
– up to 80% capacity:
150 min
– up to 100% capacity: 165 min
AL 300
with AP 80:
– up to 80% capacity:
25 min
– up to 100% capacity: 50 min
with AP 120:
– up to 80% capacity:
30 min
– up to 100% capacity: 60 min
with AP 160:
– up to 80% capacity:
35 min
– up to 100% capacity: 60 min
Cutting attachment
Cutting swath:
FSA 65:
300 mm
FSA 85:
350 mm
Length
FSA 65:
1530 mm
FSA 85:
1650 mm
Weight
without battery, with cutting attachment
and deflector
FSA 65:
2.7 kg
FSA 85:
2.8 kg
Noise and Vibration Data
Noise and vibration data are determined
on the basis of the rated maximum
speed.
For further details on compliance with
Vibration Directive 2002/44/EC see
www.stihl.com/vib/
Sound pressure level L
to EN 786
p
FSA 65:
75 dB(A)
FSA 85:
77 dB(A)
Sound power level L
to EN 786
w
FSA 65:
89 dB(A)
FSA 85:
92 dB(A)
Vibration measurement a
hv
Handle, left Handle, right
2
FSA 65:
1.3 m/s
1.1 m/s
2
FSA 85:
1.4 m/s
0.8 m/s
The K-factor in accordance with
Directive 2006/42/EC is 2.5 dB(A) for
the sound pressure level and sound
power level; the K-factor in accordance
with Directive 2006/42/EC is 2.0 m/s
for the vibration measurement.
The vibration values quoted above have
been measured according to a
standardized test procedure and may be
used to compare electric power tools.
English
to EN 786
2
2
2
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsa 85