Download Print this page

Regency Gas Insert E33-LP1 Specifications

Gas insert
Hide thumbs Also See for Gas Insert E33-LP1:

Advertisement

Model
Fuel Type
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.8" W.C. (0.95 kPa)
Manifold Pressure - Low
1.1" W.C. (0.27 kPa)
Orifi ce Size -Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Approved Venting Systems
Flex Vent Systems:
B
30°
D
H
Dimension Description
A
Faceplate Width
B
Faceplate Height
C
Unit Width
D
Unit Height
E
Unit Depth
F
Faceplate to Vent Centerline
G
Faceplate Depth
H
Height to Vent Collar
I
Optional or Standard Front Depth
June 2007 Regency Product Specifi cations Book
Gas Inserts
E33 Gas Insert
E33-NG1
E33-LP1
Natural Gas
Propane
12" W.C. (2.99 kPa)
11" W.C. (2.74 kPa)
2.9" W.C. (0.72 kPa)
#31 DMS
#50 DMS
20,000 BTU/h
19,000 BTU/h
(5.86 kW)
(5.57 kW)
38,000 BTU/h
35,500 BTU/h
(11.14 kW)
(10.40 kW)
3" Co-linear
3" Co-linear
FPI AstroCap™ Flex Vent
A
C
G
F
E
E33
45-9/16" (1157mm)
31-1/8" (791mm)
32-1/4" (819mm)
23-13/16" (605mm)
16-3/4" (426mm)
11-1/4" (286mm)
1-3/8" (35mm)
23" (583mm)
N/A

Minimum Fireplace Dimensions

The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
M
J
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
Dimension Description
J
Height
K
Width
L
Depth
M
Max. Lintel Bar Depth
N
Rear Width
E33 Gas Insert
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
L
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
K
N
Contour Faceplate
24-3/16" (614mm)
32-1/4" (819mm)
17" (432mm)
8" (203mm)
25" (635mm)
127

Advertisement

loading
Need help?

Need help?

Do you have a question about the Gas Insert E33-LP1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency Gas Insert E33-LP1

  • Page 1: Minimum Fireplace Dimensions

    Unit Height Unit Depth Faceplate to Vent Centerline Faceplate Depth Height to Vent Collar Optional or Standard Front Depth June 2007 Regency Product Specifi cations Book E33 Gas Insert E33-LP1 Propane 12” W.C. (2.99 kPa) 11” W.C. (2.74 kPa) 2.9” W.C. (0.72 kPa)
  • Page 2: Combustible Mantels

    Note: A non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour. June 2007 Regency Product Specifi cations Book 12" (305mm) Mantel 3-1/2" (89mm) Mantel 20”...

This manual is also suitable for:

E33-ng1