Model
Fuel Type
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.8" W.C. (0.95 kPa)
Manifold Pressure - Low
1.1" W.C. (0.27 kPa)
Orifi ce Size -Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Approved Venting Systems
Flex Vent Systems:
B
30°
D
H
Dimension Description
A
Faceplate Width
B
Faceplate Height
C
Unit Width
D
Unit Height
E
Unit Depth
F
Faceplate to Vent Centerline
G
Faceplate Depth
H
Height to Vent Collar
I
Optional or Standard Front Depth
June 2007 Regency Product Specifi cations Book
Gas Inserts
E33 Gas Insert
E33-NG1
E33-LP1
Natural Gas
Propane
12" W.C. (2.99 kPa)
11" W.C. (2.74 kPa)
2.9" W.C. (0.72 kPa)
#31 DMS
#50 DMS
20,000 BTU/h
19,000 BTU/h
(5.86 kW)
(5.57 kW)
38,000 BTU/h
35,500 BTU/h
(11.14 kW)
(10.40 kW)
3" Co-linear
3" Co-linear
FPI AstroCap™ Flex Vent
A
C
G
F
E
E33
45-9/16" (1157mm)
31-1/8" (791mm)
32-1/4" (819mm)
23-13/16" (605mm)
16-3/4" (426mm)
11-1/4" (286mm)
1-3/8" (35mm)
23" (583mm)
N/A
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
M
J
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
aaaaaaaaaa
Dimension Description
J
Height
K
Width
L
Depth
M
Max. Lintel Bar Depth
N
Rear Width
E33 Gas Insert
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
L
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
K
N
Contour Faceplate
24-3/16" (614mm)
32-1/4" (819mm)
17" (432mm)
8" (203mm)
25" (635mm)
127