Overview; Safety Precautions; Unintended Machine Movement; Flammable Cleaning Solvents - Sauer Danfoss 45 Series Service Manual

Frame g open circuit axial piston pumps
Table of Contents

Advertisement

oveRview

safety PReCautions

Series 45 G Frame Open Circuit Axial Piston Pumps
Service Manual
Introduction
This manual includes information for the installation, maintenance, and minor repair of
the Series 45 frame G open circuit axial piston pumps.The manual includes a description
of the units and their individual components, troubleshooting information, and minor
repair procedures. Performing installation, maintenance, and minor repair of Series 45 G
Frame axial piston pumps according to the procedures in this manual will not affect your
warranty.
Performing minor repairs requires the unit to be removed from the vehicle/machine.
Thoroughly clean the unit before beginning maintenance, or repair activities. Since dirt
and contamination are the greatest enemies of any type of hydraulic equipment, follow
cleanliness requirements strictly.This is especially important when changing the system
filter and when removing hoses or plumbing.
A worldwide network of Sauer-Danfoss authorized service Centers (ASCs) is available
for major repairs. Major repairs require the removal of the unit's endcap, which voids
the warranty unless done by an ASC. Sauer-Danfoss ASCs are trained by the factory and
certified on a regular basis.You can locate your nearest ASC using the distributor locator
at www.sauer-danfoss.com
Always consider safety precautions before beginning a service procedure. Protect
yourself and others from injury.Take these general precautions whenever servicing a
hydraulic system.

unintended machine movement

 Warning
Unintended movement of the machine or mechanism may cause injury to the technician
or bystanders. To protect against unintended movement, secure the machine or
disable / disconnect the mechanism while servicing.

flammable cleaning solvents

 Warning
Some cleaning solvents are flammable.To avoid possible fire, do not use cleaning
solvents in an area where a source of ignition may be present.

fluid under pressure

 Warning
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin
causing serious injury and/or infection.This fluid may also be hot enough to cause burns.
Use caution when dealing with hydraulic fluid under pressure. Relieve pressure in the
system before removing hoses, fittings, gauges, or components. Never use your hand
or any other body part to check for leaks in a pressurized line. Seek medical attention
immediately if you are cut by hydraulic fluid.

Personal safety

 Warning
Protect yourself from injury. Use proper safety equipment, including safety glasses, at all
times.
520L0605 • Rev AB • December 2010
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 45 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents