auxiLiaRy PaDs

Caution
Shipping cover is intended
only to retain coupling
during shipment and
storage. Do not operate
pump with coupling and
shipping cover installed.
J120
J110
h
3
t91 - 111 N•m
[67 - 82 lbf•ft]
24
Series 45 G Frame Open Circuit Axial Piston Pumps
Service Manual
Minor repair
You may install auxiliary mounting pads on pumps equipped with through-drive radial
ported end caps. Follow these steps to either remove, replace, or exchange auxiliary
mounting pads.

Removal

1. Remove the screws (J130), retaining the cover plate (J110) or auxiliary pump (not
shown). Remove the shipping cover or auxiliary pump and its seal (J120).
2. Remove the drive coupling (J140) if present.
3. Remove the 4 screws (J100) retaining the pad adapter (J080) to the endcap. Discard
the pad adapter O-ring (J090) if present.

installation

4. Lubricate new O-ring (J090) with petroleum jelly. Install the pad adapter to the
endcap.
5. Install the 4 screws (J100 ) and torque to 47.5 - 61 N•m [35 - 45 lbf•ft].
6. Install the drive coupling (J140) if present.
7. Install shipping cover or auxiliary pump with seal (J120).
8. Install the screws (J130) and torque to 94 - 115 N•m [67 - 82 lbf•ft]. If you have an
auxiliary A pad, install the screws (J131) and torque to 37 - 50 N•m [27 - 37 lbf•ft].
Auxiliary mounting pads
J140
J080
J100
I10 mm
t47.5 - 61 N•m
[35 - 45 lbf•ft]
J130
J110
/
inch
4
520L0605 • Rev AB • December 2010
dg
J090
J095
J095
J080
J140
J120
J100
J120
P106 029E
J110
J130
h
3
/
inch
4
t91 - 111 N•m
[67 - 82 lbf•ft]
dg
J090
J095
J080
J140
J120

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 45 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel