HP 1200 W Common Slot Platinum Plus Hot-Plug Power Supply
(94% efficiency)
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
HP 1500 W Common Slot Platinum Plus Hot-Plug Power Supply
(94% efficiency)
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
Value
100 VAC,100 to 120 VAC
50 Hz to 60 Hz
9.2 A at 100 VAC
9.5 A at 110 to 120 VAC
6.6A at 200 to 240 VAC
1000 W at 120V AC input
1320 W at 230V AC input
3408 at 120V AC input
4500 at 230V AC input
800W at 100V AC input (low line)
900W at 108V to 132V AC input
(low line)
1200 W at 200V to 240V AC
input (High line)
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Value
200 to 240 VAC
50 Hz to 60 Hz
8.3 A at 200 VAC
1652 W at 230V AC input
5637 at 230V AC input
1500 W
1500 W at 200V to 240V AC input
1500 W at 200V to 240V AC input