50
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
FILL DRUM WITH CALIBRATION WEIGHT
ENTER WEIGHT IN HG AND
PRESS SELECT
SELECT
4785
SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
DONE! PRESS SELECT
SELECT
3588
SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
REMOVE WEIGHT AND PRESS SELECT
SELECT
3588
SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
PRESS SELECT FOR ZERO CALIBRATION
SELECT
3588
SELECT
Procedure for use
For machines with weighing equipment installed only!
Put the calibration
weight in the drum.
Use the numeric keys
to enter the calibration
weight in hg (1 hg = 100
grams).
Press SELECT.
Press SELECT.
Remove the calibration
weight.
Press SELECT.
If you want to use the
"Calibrate zero" function
now:
Press SELECT.
Calibration weight
A weight of between 40 kg and 400 kg should be
used as a calibration weight.
The higher the weight (within these limits), the better
the weighing accuracy of the machine.