Install Diagnostics - Maytag W10393006 Service Manual

Table of Contents

Advertisement

Available languages

Available languages

FOR SERVICE TECHNICIAN'S USE ONLY

INSTALL DIAGNOSTICS

NOTE: The Service Diagnostic Mode must be
activated before entering Install Diagnostics;
see procedure on page 3.
NOTE: If, at any point, the user presses the
"power" button or opens the door during Install
Diagnostics, the dryer exits to standby mode.
Active Fault Code Display
in Install Diagnostics
If the display begins flashing while in Install
Diagnostics, it is displaying an active fault
code. Active fault codes are codes that are
currently detected. Only one active fault code
can be displayed at a time.
STEP TEST TEST
1
Dryer starts L2 detection algorithm.
L
1
L
L2 detection complete.
2
2
D
&
E
Dryer starts L1 detection algorithm.
T
3
Airflow detection starts at this step.
L
E
1
C
L1 detection complete.
T
4
CCU calculates L1 to L2.
t
o
A
I
Press the START button to cycle
L
R
5
through L1, L2, and L1 to L2.
2
F
L
O
W
6
Airflow test near completion.
Airflow detection complete.
7
Press the START button to begin
W
8
water system test.
A
T
Steam test running. LED drum light
E
9
and water turn on.
R
* Dryer performance is optimized for 2-phase, 240 V AC service. If complaint is made regarding dryer performance and the L1 to L2 voltage
is ~208 V AC, dryer may be connected to a 3-phase service with reduced wattage that will decrease dryer performance. Also check the
Customer Focused Dryness Level setting (see page 19).
DO NOT REMOVE OR
INSTALL DIAGNOSTICS
DRYER FUNCTION
DESTROY
Entry Procedure
To enter Install Diagnostics, press and release
the 2
button used to activate the Service
nd
Diagnostic mode. All LEDs turn off and the
"start/pause" button begins to flash.
WATER-ONLY TEST: Press and hold the "start/
pause" button for ~2–5 seconds to run only
the water system test.
PERFORM ALL TESTS: Press and release the
"start/pause" button to run the tests indicated
in the chart below.
Exit Procedure
When test is complete, press the "power"
button to exit Install Diagnostics and return
to standby mode. Opening and closing the
door will also exit the test mode.
COMPONENT
Motor On
Display shows "- - -" until voltage is
Heater On/Off
available at UI.
• If Electric: Display L2 level (range 0
Motor On
to 200).
Heater On
• If Gas: Display "9as" for gas since L2
does not exist.
Motor On
L2 continues to be displayed.
Heater On
Motor On
Once L1 is calculated, L1 to L2 is
Heater On/Off
immediately calculated in the CCU.
• L1 voltage should be 120 V AC ± 10%.
• L2 voltage should be 120 V AC ± 10%,
Motor On
or "9as" if gas dryer.
Heater On/Off
• L1 to L2 voltage should be 240* V AC
± 10%, or "9as" if gas dryer.
Motor On
The display will count down the final 15
Heater On/Off
seconds of the AirFlow detection routine.
When the airflow routine is complete,
Motor Off
the seven-segment display will show
Heater Off
airflow result (0=BAD, 1=GOOD,
2=INVALID).
Water Valve On
Display shows "h28" when running.
Drum Light On
Water Valve On
Water and LED drum light are actuated
Drum Light On
for 30 seconds.
NOTES
PAGE 5

Advertisement

Table of Contents
loading

Table of Contents