4 TEST AND MEASUREMENTS

4.a
Charging measurements
To check the charging, we uses a modified AC/DC and an ampermeter connected as follow :
Mobile with
empty battery
without SIM
When you plug the charger into the wall socket, the charging current is displayed by ampermeter
The charging indicator scroll on the LCD and the red top led lights up.
During pre-charge, the value of the curent is 84 mA (measurment without backlight)
During rapid charge, the value of the current is 610 mA (measurment without backlight)
For more details about charging, see the LEVEL 3 SERVICE MANUAL FA9M037910 at page 5.
Mitsubishi Electric Telecom Europe
Version C
ZA le Piquet, 35370 Etrelles
Date: 05/00
Phone: +33 2 99 75 71 00
7/20