6 SOFTWARE AND SETTING VERSION

To display the software and the perso (personalisation), connect a charged battery, press the power key. Wait a
few seconds, then hold the * key and press 5807.
Then on the mobile, the following message is displayed
For example:
To exit from the Software and Perso monitoring mode, press any key except power key

7 OPERATOR DEBUGGING

To display the RX level (in dBm), insert the SIM card (from service provider or test SIM card using CMD in
manual test) , connect a charged battery and press the power key. When the mobile displays the network (real
network or test network 001-01) ,hold the * key and press 4329
Then on the mobile, the following message is displayed
For example :
To exit from the Operator debugging mode, uses the same command : hold the * key and press 4329
Mitsubishi Electric reserves the right to make changes to its products at any time to improve reliability or
manufacturability. Mitsubishi Electric does not assume any liability arising from the uses of any device or
circuit described herein, nor does it convey any license under its patent rights or the rights of others.
Version C
Date: 05/00
20/20
- - VERSION - - -
21157001
- - - PERSO - - - -
21433S00
B099 07 -085
MCC001 MNC01
1.a.1.1.1.1.1.1
And
other
datas
...
Level 2 Service Manual
RX level (dBm)
Mitsubishi Electric Telecom Europe
ZA le Piquet, 35370 Etrelles
Phone: +33 2 99 75 71 00
Fax: +33 2 99 75 71 47
ARIA