Pioneer PRO-810HD Service Manual page 111

Hide thumbs Also See for PRO-810HD:
Table of Contents

Advertisement

5
3. COMMON-PANEL1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1
C OMMO
N – P A N E L 1
2
3
4
5
6
7
8
9
10
11
12
13
14
X – S U S
U 1
15
16
Each time the 5 or ∞ key is pressed, the subitems are changed, as follows:
Corresponding 232C
No.
Function/Display
Command
1
XU1
X-SUS U1 <=>
2
XU2
X-SUS U2 <=>
3
XD1
X-SUS D1 <=>
4
XD2
X-SUS D2 <=>
5
YU1
Y-SUS U1 <=>
6
YU2
Y-SUS U2 <=>
7
YD1
Y-SUS D1 <=>
8
YD2
Y-SUS D2 <=>
9
YD3
Y-SUS D3 <=>
10
YD4
Y-SUS D4 <=>
11
VSU
VLT-SUS <=>
12
VOF
VLT-OFS <=>
"∗∗∗" in the table above represents the adjustment value.
The value of each subitem can be changed using the 2 or 3 key.
Notes:
• Adjustments No. 1 to No. 10 above are not normally required, unless so instructed by Service Information, etc.
• Readjustment of values for No. 11 [VSU] and No. 12 [VOF] are required when the service panel is replaced.
5
6
I N 1 – G 3 2 – R G B – A H M
< = >
: 1 2 8
: ∗∗∗
Adjustment of X-SUS leading edge pulse U1
: ∗∗∗
Adjustment of X-SUS leading edge pulse U2
: ∗∗∗
Adjustment of X-SUS trailing edge pulse D1
: ∗∗∗
Adjustment of X-SUS trailing edge pulse D2
: ∗∗∗
Adjustment of Y-SUS leading edge pulse U1
: ∗∗∗
Adjustment of Y-SUS leading edge pulse U2
: ∗∗∗
Adjustment of Y-SUS trailing edge pulse D1
: ∗∗∗
Adjustment of Y-SUS trailing edge pulse D2
: ∗∗∗
Adjustment of X-SUS trailing edge pulse D3
: ∗∗∗
Adjustment of X-SUS trailing edge pulse D4
: ∗∗∗
SUS voltage adjustment
: ∗∗∗
OFFSET voltage adjustment
PRO-1010HD
6
7
Content
7
8
A
B
Adjustable Range
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
C
124 to 132
124 to 132
000 to 255
000 to 255
D
E
F
111
8