5
4. PANEL PD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1
I
N F O R M A T I O N
2
3
P
A N E
L
P
D
4
F
I R S T
5
6
1
X – D R V
7
2
Y – S U S
8
3
S C A N
9
10
4
Y – D C C
D
5
S C N –
5
11
6
A D R S
12
7
13
8
14
15
16
The log of the past eight power-downs is displayed. Power-down points (first and second) and the hour meter value when the
power-down was generated are displayed, with the latest power-down data at the top.
The meanings of indications for power-down points are shown in the table below.
• Power-down information
Type of Power-down
No corresponding item
Power-down of the main power supply
system
Power-down of the scanning system
Power-down in the path between the
scanning system and 5-V power supply
Power-down of the Y-Drive system
Power-down of the Y-DC/DC converter
PD which cannot be specified
1: If an activated protection circuit could not be identified after the power-down, it is treated as an unidentifiable power-down (UNKNOWN).
5
6
I N 1 – G 3 2 – R G B – A H M
S E C O N D
P
OWE R
0 0 5 2 3 H 5 1 M
Y
– D C D C
0 0 2 7 5 H 4 2 M
– – – –
0 0 0 9 0 H 5 0 M
P
OWE R
0 0 0 4 3 H 0 3 M
V
P
OWE R
0 0 0 0 2 H 3 1 M
– – – –
0 0 0 0 0 H 0 7 M
On-Screen Display
- - - - -
POWER
SCAN
SCN-5V
Y-DRV
Y-DCDC
UNKNOWN
6
7
H
M
H
M
Type of Power-down
Power-down of the Y-SUS system
Power-down of the address system
Power-down of the X-DRIVE circuitry
Power-down of the X-DC/DC converter
Power-down of the X-SUS system
Power-down of the driving IC power
supply system
PRO-1010HD
7
8
On-Screen Display
Y-SUS
ADRS
X-DRV
X-DCDC
X-SUS
D-DCDC
101
8
A
B
C
D
E
F