Panasonic S-200PE2E5 Technical Data & Service Manual page 10

Dc inverter
Table of Contents

Advertisement

1 1
Single-Type
High Static Pressure Ducted Type S-200PE1E8A / U-200PE1E8
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)
Moisture removal (High)
External static pressure (High)
ELECTRICAL RATINGS
Voltage ratings
Available voltage range
Running amperes*
Max–Running amperes**
Power input
C.O.P
Max.Starting amperes
FEATURES
Controls / Thermostat control
Timer
Fan speeds Indoor / Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound
Color
(Approximate value)
REFRIGERANT TUBING
Limit of tubing length
Limit of tubing length at shipment
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipment
DIMENSIONS & WEIGHT
Unit dimensions
Package dimensions
Net weight
Shipping weight
Shipping volume
NOTE
*1 There are two types of supplied tubings. The one tubing port ø19.05 (flare process) is connected to the flared connection of the gas port
side's service valve. The other "L" shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):
Full load conditions (**):
Heating:
Rating conditions (*):
Full load conditions (**):
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
kW
BTU / h
m
3
Liters / h
Pa (mmAq)
kW
W / W
Indoor - Hi / Me / Lo
dB-A
Outdoor - Hi
dB-A
Indoor
Outdoor
m (ft.)
m (ft.)
m (ft.)
Liquid tube
mm (in.)
Gas tube
mm (in.)
kg
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
kg (lb.)
kg (lb.)
m
3
(cu.ft)
Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
220-230-240V, 50Hz, single-phase
380-400-415V, 50/60Hz, 3-phase
Cooling
20.0 [6.0~22.4]
68,200 [20,500~76,400]
/ h
11.1
216 (22): at shipment 235 (24): using the booster cable
V
380
400
V
342~456(Outdoor) 198~264(Indoor)
A
12.2
11.8
A
7.58
7.64
2.64
2.62D
A
Microprocessor / I.C.thermostat
3 and Automatic control / Variable
Wired: CZ-RTC2 / Wireless: CZ-RWSC2
25A Male screw (No Drain Pump)
57
Indoor unit
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
9.52 (3 / 8)
25.4 (1)*
Indoor unit
479 (18-55 / 64)
1,428 (56-7 / 32)
1,230 (48-27 / 64)
619 (24-3 / 8)
1,536 (60-15 / 32)
1,339 (52-23 / 32)
120 (265)
144 (317)
1.273 (44.9)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1-4
S-200PE1E8A
U-200PE1E8
Heating
21.8 [6.0~22.4]
74,400 [20,500~76,400]
4,320 / 4,200 / 3,960
415
380
400
11.5
9.8
9.5
7.70
6.09
6.15
2.60
3.58
3.54B
ON / OFF 72-hours
Field supply
Rotary
51 / 50 / 49
57
Munsell 1Y 8.5 / 0.5
Outdoor unit
100 (328)
5~30(16~98)
9.52 (3 / 8)
1
25.4 (1)*
R410A - 5.3
Outdoor unit
1526 (60-5 / 64)
940 (37-1 / 64)
340 (13-25 / 64)
1676 (65-63 / 64)
1076 (42-23 / 64)
420 (16-17 / 32)
118 (260)
128 (282)
0.757 (26.7)
415
9.3
6.21
3.51
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents